DIMENSIONAL SPECIFICATIONS LIVS24HP230V1B
INDOOR UNIT DIMENSIONS Units: inch
Model No: LIVS24HP230V1BH
A 42.4
B 12.8
C 9.7
Weight (Net/Gross) 37.5/45.2 lbs
Liquid Line Valve 1/4-in OD Flared
Gas Line Valve 5/8-in OD Flared
Drain Connector 5/8-in OD
OUTDOOR UNIT DIMENSIONS Units: inch
Model No: LIVS24HP230V1BO
A 22.0
B 15.3
C 27.6
D 38.0
E 14.3
Weight (Net/Gross) 110.3/120.2 lbs
Liquid Line Valve 1/4-in OD Flared
Gas Line Valve 5/8-in OD Flared
Notes:
1. Recommended Interconnecting Cable Type 14 AWG 4 Stranded Copper Conductors THHN 600V Wire
2. Power wiring cable size must comply with applicable national and local codes.
3. Test conditions are based on AHRI 210/240.