SAFETY DATA SHEET Genetron® 410A 000000009881 Version 2.7 Revision Date 04/18/2014 Print Date 04/14/2015 SECTION 1. PRODUCT AND COMPANY IDENTIFICATION Product name : Genetron® 410A MSDS Number : 000000009881 Product Use Description : Refrigerant Manufacturer or supplier's details : Honeywell International Inc.
SAFETY DATA SHEET Genetron® 410A 000000009881 Version 2.7 Revision Date 04/18/2014 Print Date 04/14/2015 Symbol(s) : Signal word : Warning Hazard statements : Contains gas under pressure; may explode if heated. May displace oxygen and cause rapid suffocation. Precautionary statements : Prevention: Use personal protective equipment as required. Storage: Protect from sunlight. Store in a well-ventilated place. Hazards not otherwise classified : May cause eye and skin irritation.
SAFETY DATA SHEET Genetron® 410A 000000009881 Version 2.7 Revision Date 04/18/2014 Print Date 04/14/2015 Inhalation : Move to fresh air. If breathing is irregular or stopped, administer artificial respiration. Use oxygen as required, provided a qualified operator is present. Call a physician. Do not give drugs from adrenaline-ephedrine group. Skin contact : After contact with skin, wash immediately with plenty of water.
SAFETY DATA SHEET Genetron® 410A 000000009881 Version 2.7 Revision Date 04/18/2014 Print Date 04/14/2015 Do not allow run-off from fire fighting to enter drains or water courses. Vapours are heavier than air and can cause suffocation by reducing oxygen available for breathing.
SAFETY DATA SHEET Genetron® 410A 000000009881 Version 2.7 Revision Date 04/18/2014 Print Date 04/14/2015 SECTION 7. HANDLING AND STORAGE Handling Handling : Handle with care. Avoid inhalation of vapour or mist. Do not get in eyes, on skin, or on clothing. Wear personal protective equipment. Use only in well-ventilated areas. Pressurized container. Protect from sunlight and do not expose to temperatures exceeding 50 °C.
SAFETY DATA SHEET Genetron® 410A 000000009881 Version 2.7 Revision Date 04/18/2014 Print Date 04/14/2015 Avoid contact with skin, eyes and clothing. Ensure that eyewash stations and safety showers are close to the workstation location. Engineering measures : General room ventilation is adequate for storage and handling. Perform filling operations only at stations with exhaust ventilation facilities.
SAFETY DATA SHEET Genetron® 410A 000000009881 Version 2.7 Revision Date 04/18/2014 Exposure Guidelines Components CAS-No. Value Print Date 04/14/2015 Control parameters 2,200 mg/m3 (1,000 ppm) Upda te 2007 Basis Difluoromethane 75-10-5 TWA : time weighted average Difluoromethane 75-10-5 TWA : time weighted average (1,000 ppm) 1994 Honeywell:Limit established by Honeywell International Inc. Pentafluoroethan e 354-33-6 TWA : time weighted average 4,900 mg/m3 (1,000 ppm) 2007 WEEL:US.
SAFETY DATA SHEET Genetron® 410A 000000009881 Version 2.7 Revision Date 04/18/2014 Print Date 04/14/2015 Boiling point/boiling range : -48.5 °C Flash point : Note: not applicable Evaporation rate : >1 Method: Compared to CCl4. lower flammability limit : Note: None upper flammability limit : Note: None Vapor pressure : 14,844 hPa at 21.1 °C(70.0 °F) 33,798 hPa at 54.4 °C(129.9 °F) Vapor density : 3 Note: (Air = 1.0) Density : 1.08 g/cm3 at 21.
SAFETY DATA SHEET Genetron® 410A 000000009881 Version 2.7 Global warming potential (GWP) Ozone depletion potential (ODP) Revision Date 04/18/2014 Print Date 04/14/2015 : 1,975 : 0 SECTION 10. STABILITY AND REACTIVITY Chemical stability : Stable under normal conditions. Possibility of hazardous reactions Conditions to avoid : Hazardous polymerisation does not occur. : Pressurized container. Protect from sunlight and do not expose to temperatures exceeding 50 °C. Decomposes under high temperature.
SAFETY DATA SHEET Genetron® 410A 000000009881 Version 2.
SAFETY DATA SHEET Genetron® 410A 000000009881 Version 2.
SAFETY DATA SHEET Genetron® 410A 000000009881 Version 2.7 Revision Date 04/18/2014 Print Date 04/14/2015 cardiac arrhythmia. SECTION 12. ECOLOGICAL INFORMATION Biodegradability Pentafluoroethane Difluoromethane : Result: Not readily biodegradable. Value: 5 % Method: OECD 301 D : Note: Minimal Further information on ecology Additional ecological information : This product is subject to U.S. Environmental Protection Agency Clean Air Act Regulations at 40 CFR Part 82.
SAFETY DATA SHEET Genetron® 410A 000000009881 Version 2.7 Revision Date 04/18/2014 Class Packing group Hazard Labels IATA 2.2 2.2 UN/ID No. Description of the goods Class Hazard Labels Packing instruction (cargo aircraft) Packing instruction (passenger aircraft) IMDG Print Date 04/14/2015 UN/ID No. Description of the goods Class Hazard Labels EmS Number Marine pollutant : UN 3163 : LIQUEFIED GAS, N.O.S. (Pentafluoroethane, Difluoromethane) : 2.2 : 2.2 : 200 : 200 : UN 3163 : LIQUEFIED GAS, N.O.S.
SAFETY DATA SHEET Genetron® 410A 000000009881 Version 2.7 Revision Date 04/18/2014 Print Date 04/14/2015 Korea. Toxic Chemical Control Law (TCCL) List : On the inventory, or in compliance with the inventory Philippines. The Toxic Substances and Hazardous and Nuclear Waste Control Act : On the inventory, or in compliance with the inventory China.
SAFETY DATA SHEET Genetron® 410A 000000009881 Version 2.7 Revision Date 04/18/2014 Print Date 04/14/2015 This product has been classified according to the hazard criteria of the CPR and the MSDS contains all of the information required by the CPR. Global warming potential : 1,975 Ozone depletion potential (ODP) : 0 SECTION 16. OTHER INFORMATION Health hazard Flammability Physical Hazard Instability HMIS III : 1 : 1 : 0 : NFPA 2 1 0 Hazard rating and rating systems (e.g.
Article Information Sheet (AIS) This Article Information Sheet (AIS) provides relevant battery information to retailers, consumers, OEMs and others users requesting a GHS‐compliant SDS. Articles, such as batteries, are exempt from GHS SDS classification criteria. The GHS criteria is not designed or intended to be used to classify the physical, health and environmental hazards of an article. Branded consumer batteries are defined as electro‐technical devices.
Article Information Sheet (AIS) Ingestion/Small Parts Warning Normal Conditions of Use Note to Physician First Aid ‐ If swallowed First Aid ‐ Eye Contact First Aid ‐ Skin Contact First Aid ‐ Inhalation Required for Small Cell or Battery (Sizes: AAA and Specialty Cells): Keep away from children. If swallowed, consult a physician immediately. Exposure to contents inside the sealed battery will not occur unless the battery leaks, is exposed to high temperatures, or is mechanically abused.
Article Information Sheet (AIS) USA EPA RCRA (40 CFR 261) Classified as non‐hazardous waste (not ignitable, corrosive, reactive or toxic). Federal Universal Waste Regulations (40 CFR 273) do not apply. State requirements may be more stringent than Federal. California Universal Waste Rule (Cal. California prohibits disposal of batteries as trash (including household trash). Code Regs. Title 22, Div. 4.5, Ch. 23) 9. Transport Information (GHS Section 14) Not regulated.
Article Information Sheet (AIS) 10c. Regulatory Definitions ‐ Articles USA OSHA 29 CFR 1910.1200(b)(6)(v) USA TSCA 40 CFR 704.3; 710.2(3)( c); and [19 CFR 12.1209a)] EU REACH Title 1 ‐ Chapter 2 ‐ Article 3(3) GHS Section 1.3.2.1 11. Other Information 11a. Certification & 3rd Party Approvals AA, 9V UL (UTGT2.S50939 Single Multiple Station Smoke Alarms ‐ Component) Certification Standard: ANSI/UL 217 Single & Multiple Station Smoke Alarms 11b.