Multi Outdoor Units Technical Product Guide

26
INDOOR UNIT COMBINATIONS
+Multi Outdoor Units
Model No: MULTI42HP230V1A 42,000 BtuH (cont.)
Heating Capacity (BtuH)
12K+12K+18K 44,357 15,354~45,040 13,648 13,648 17,060
12K+12K+24K (2) 45,040 15,354~47,769 11,454 11,454 22,131
12K+18K+18K 45,040 15,354~47,769 10,871 17,084 17,084
12K+18K+24K (2) 45,040 15,354~47,769 10,291 16,112 18,637
12K+24K+24K (2) 45,040 15,354~47,769 9,707 17,668 17,668
18K+18K+18K 45,040 15,354~47,769 14,948 14,948 15,143
18K+18K+24K (2) 45,040 15,354~47,769 13,979 13,979 17,084
9K+9K+9K+9K 44,357 15,354~47,769 11,089 11,089 11,089 11,089
9K+9K+9K+12K 44,357 15,354~47,769 10,236 10,236 10,236 13,648
9K+9K+9K+18K 45,040 15,354~47,769 8,929 8,929 8,929 18,248
9K+9K+9K+24K (2) 45,040 15,354~47,769 7,766 7,766 7,766 21,742
9K+9K+12K+12K 44,357 15,354~47,769 8,956 8,956 13,222 13,222
9K+9K+12K+18K 45,040 15,354~47,769 7,766 7,766 12,038 17,473
9K+9K+12K+24K (2) 45,040 15,354~47,769 7,182 7,182 10,871 19,995
9K+9K+18K+18K 45,040 15,354~47,769 7,377 7,377 15,143 15,143
9K+9K+18K+24K (2) 45,040 15,354~47,769 6,988 6,988 11,843 19,220
9K+12K+12K+12K 45,040 15,354~47,769 8,929 12,038 12,038 12,038
9K+12K+12K+18K 45,040 15,354~47,769 8,155 9,902 9,902 17,084
9K+12K+12K+24K (2) 45,040 15,354~47,769 7,377 9,028 9,028 19,609
9K+12K+18K+18K 45,040 15,354~47,769 7,377 9,318 14,170 14,170
9K+18K+18K+18K 45,040 15,354~47,769 6,599 12,812 12,812 12,812
12K+12K+12K+12K 45,040 15,354~47,769 11,260 11,260 11,260 11,260
12K+12K+12K+18K 45,040 15,354~47,769 9,513 9,513 9,513 16,501
12K+12K+12K+24K (2) 45,040 15,354~47,769 8,540 8,540 8,540 19,415
12K+12K+18K+18K 45,040 15,354~47,769 8,929 8,929 13,590 13,590
9K+9K+9K+9K+9K 45,040 15,354~47,769 9,008 9,008 9,008 9,008 9,008
9K+9K+9K+9K+12K 45,040 15,354~47,769 8,445 8,445 8,445 8,445 11,260
9K+9K+9K+9K+18K 45,040 15,354~47,769 7,766 7,766 7,766 7,766 13,979
9K+9K+9K+9K+24K (2) 45,040 15,354~47,769 7,377 7,377 7,377 7,377 15,532
9K+9K+9K+12K+12K 45,040 15,354~47,769 8,155 8,155 8,155 10,291 10,291
9K+9K+9K+12K+18K 45,040 15,354~47,769 7,377 7,377 7,377 9,414 13,491
9K+9K+9K+18K+18K 45,040 15,354~47,769 7,377 7,377 7,377 11,454 11,454
9K+9K+12K+12K+12K 45,040 15,354~47,769 7,377 7,377 10,096 10,096 10,096
9K+9K+12K+12K+18K 45,040 15,354~47,769 6,793 6,793 9,124 9,124 13,201
9K+12K+12K+12K+12K 45,040 15,354~47,769 7,377 9,414 9,414 9,414 9,414
9K+12K+12K+12K+18K 45,040 15,354~47,769 6,988 8,639 8,639 8,639 12,133
12K+12K+12K+12K+12K 45,040 15,354~47,769 9,008 9,008 9,008 9,008 9,008
INDOOR UNITS
COMBINATIONS
RATED
SYSTEM
CAPACITY
(BtuH)
CAPACITY
RATING
(MIN – MAX)
(BtuH)
INDOOR
UNIT A
(BtuH)
INDOOR
UNIT B
(BtuH)
INDOOR
UNIT C
(BtuH)
INDOOR
UNIT D
(BtuH)
INDOOR
UNIT E
(BtuH)
Notes: 1) It is critical to size the outdoor unit for the entire building load and each indoor unit for its individual zone load.
2) 24K size is reserved for Ceiling Cassettes, Concealed Ducts, and Floor/Ceilings units only. Not Wall Mount units.
Capacity data is based on the following conditions:
Cooling Nominal Test Conditions: Heating Normal Test Conditions
Indoor: 80°F DB/67°F WB Indoor: 70°F DB/60°F WB
Outdoor: 95°F DB/75°F WB Outdoor: 47°F DB/43°F W