Memory card error Flash 16 times
EE
Compressor demagnetizing
protection
Flash 17 times
HE HE
Compressor desynchronizing Flash 18 times
H7 H7
Compressor phase lack Flash 19 times
U2 U2
Compressor phase circuit detection
error
Flash 20 times
U1 U1
Compressor power protection Flash 21 times
L9 L9
Compressor discharge temperature
protection
Flash 23 times
E4 E4
Lack of refrigerant or jam protection Flash 31 times
F0 F0
Normal operation Flash 1 time
Frequency limitation for AC current Flash 2 times
F8
Oil returning Flash 3 times
F7
Defrosting Flash 4 times
H1 H1
Frequency limitation for IPM
temperature
Flash 5 times
EU
Frequency limitation for PFC
temperature
Flash 6 times
EU
Frequency limitation for compressor
overload
Flash 8 times
LU
Frequency limitation for compressor
discharge temperature
Flash 9 times
F9
Frequency limitation for low pressure Flash 10 times
Pn
Frequency limitation for high
pressure
Flash 11 times
F6
Discharge temperature sensor error Flash 12 times
F5 F5
Outdoor temperature sensor error Flash 13 times
F3 F3
Suction temperature sensor error Flash 15 times
dc
Condenser temperature sensor error Flash 16 times
A7 A7
Low pressure sensor error Flash 18 times
dL
High pressure sensor error Flash 19 times
e1
Fan motor error for indoor unit Flash 20 times
H6 H6
Driving board is connected Flash 1 time
Testing board is connected Flash 2 times
Computer is connected Flash 4 times
Indoor unit 1 is connected Flash 5 times
Indoor unit 2 is connected Flash 6 times
Indoor unit 3 is connected Flash 7 times
Indoor unit 4 is connected Flash 8 times
Indoor unit 5 is connected Flash 9 times
Middle pressure sensor error
FU
Intermediate vapor injection
temperature sensor error
Fb