Troubleshooting
This unit has onboard diagnostics. Error codes will appear on the LED display on the front panel of the
indoor unit in place of the temperature display. The table below explains the error codes for both units.
START-UP
Step 11
Installing Photocatalytic Filter (optional)
1. Lift front panel and remove air filter. (Fig. a).
2. Attach photocatalytic filter onto air filter. (Fig. b).
3. Install air filter as shown; close panel. (Fig. c).
Step 12
Start-up and Checkout
Test Operation
Perform test operation after completing gas leak and electrical safety check.
1. Turn on electrical disconnect to outdoor unit.
2. Push the ON/OFF” button on Remote Control to begin testing.
NOTE: A protection feature prevents the system from being activated for approx. 3 minutes.
3. Push MODE button, select COOLING, HEATING, FAN mode to confirm all functions.
System Checks
1. Conceal refrigerant pipes where possible. 2. Make sure drain hose slopes downward
along entire length. 3. Ensure all refrigerant pipes and connections are properly insulated.
4. Fasten pipes to outside wall, when possible. 5. Seal and weatherproof wall hole which
the interconnecting wires and refrigerant pipes pass through.
Indoor Unit
1. Do all Remote Control buttons function properly? 2. Do the display panel lights work properly?
3. Does the swing louver function properly? 4. Does the drain work?
Outdoor Unit
1. Push the mode button to COOL and adjust the room setting to 6F deg. Wait up to 3 minutes
from compressor time guard. Does compressor and outdoor fan turn on in cooling mode?
2. Push the mode button to HEAT and adjust the room setting to 8F deg. Wait up to 3 minutes
for compressor time guard. Does compressor and outdoor fan turn on in heat mode?
START-UP AND TROUBLESHOOTING
Explain Following Items To Customer With The Aid Of The Owners Manual:
1. How to turn system on and off; selecting C OOLING, HEATING and other operating modes;
setting a desired temperature; setting the timer to automatically start and stop system
operation; and all other features of the Remote Control and display panel.
2. How to remove and clean the air filter.
3. How to set air with the swing louvers.
4. Explain care and maintenance.
5. Present the Owner’s Manual and installation instructions to customer.
DIAGNOSTIC CODES
Fig. a
Air Filter
Photocatalytic
Filter
Fig. b
Fig. c
Equipment Fault
Indoor Configuration Jumper
Indoor/Outdoor Mismatch
High Current Protection
Communication Error
Indoor Air Temp. Thermistor
Indoor Coil Temp. Thermistor
Outdoor Air Temp. Thermistor
Outdoor Coil Temp. Thermistor
Compressor Discharge Temp. Thermistor
Compressor Overload Protection
IPM Module Protection
Indoor Fan Malfunction
Compressor Synchronism
4-Way Valve Malfunction
Defrost Mode
Possible Causes
Missing Configuration Jumper on Indoor Control Board
Indoor and Outdoor Units Do Not Match (Model or Capacity)
Power Supply is not Stable and Voltage Range is too Large
Mis-wired or Communication Failure
Bad Connection, or Indoor Air Sensor Failure
Bad Connection, or Indoor Coil Sensor Failure
Bad Connection, or Outdoor Ambient Sensor Failure
Bad Connection, or Outdoor Coil Sensor Failure
Bad Connection, or Discharge Sensor Failure
Low Refrigerant Charge, Blocked Capillary, or Compressor Motor Failure
IPM Module Temperature Too High, High Ambient, Low Voltage, or Bad Connections
Indoor Fan Stopped or Running too Slow
High Pressure, Low Voltage, or Bad Connections
Bad Connection, Solenoid Failure, or Valve Malfunction. ( Heat Pumps Only)
No failure, system is defrosting indoor coil.
Error Codes
C5
LP
E5
E6
F1
F2
F3
F4
F5
H3
H5
H6
H7
U7
H1
TWD-0813-032 Neo install REV:Layout 1 9/27/13 12:15 PM Page 23
E1
High Pressure Protection
Too much refrigetant or High Ambient conditions or low airflow.