Use and Care Manual

6
3.2.2 Outdoor Unit
The unit should be installed level right to left and front to back.
During installation, if the outdoor unit has to be exposed to strong wind, it must be properly secured.
If possible, do not install the unit where it will be exposed to direct sunlight.
(1). Install the outdoor unit at a place where there's not much dust .
(2). Install the outdoor unit where it is convenient to connect with the indoor unit.
(3). Install the outdoor unit where the condensate water can be drained out freely during
heating operation.
(4). Do not place animals and plants in the path of the warm discharge air.
(5). Take the air conditioner weight into account .
(6). Install the outdoor unit in a location that is capable of withstanding the weight
of the unit.
(7).
Provide the minimum installation clearance dimensions
shown in Fig.3.2, so that the air ow is not blocked.
Units: mm(inch)
>500mm (20inch)
>500mm (20inch)
>500mm
>500mm
(20inch)
>610mm(24inch)
>1850mm
(72inch)
Fig. 3.2
3.3 Connection Pipe Requirement
The maximum length of the connection pipe is listed in the table below. Do not install the unit in the location
where the distance exceeds the maximum length of the connection pipe.
U-match Series Cassette Type Unit
Indoor Unit
Outdoor Unit
.
.
①
②
(20inch)
>500mm
(20inch)