4.7 Electrical Wiring
4.7.1 Wiring Precautions
.
Before obtaining access to electrical terminals, disconnect all electrical power .
.
Before turning on the unit, verify that the voltage is within the 187~2
52V range(for single phrase unit).
.
Always use a independent circuit and install a independent outlet to supply power
to the air conditioner.
.
Use a circuit breaker and independent outlet for the electrical rating of the air conditioner.
.
.
Wiring work should be performed according to national electrical (NEC) and local standards.
so that the air conditioner can operate properly.
Install a leakage circuit or GFI breaker in accordance with the related laws and regulations
and electric company standards.