Use and Care Manual

24
When the air conditioner won't start due to low voltage, please contact a licensed electrician.
4.7.2 Electrical Wiring
(1). For solid core wiring (Fig. 4.36)
1). Cut the wire end with a wire cutter or wire-cutting pliers, then strip the insulation about
25mm (1inch).
2). Using a screwdriver, remove the terminal screw(s) on the terminal board.
3). Using pliers, bend the solid wire to form a loop suitable for the terminal screw.
4). Shape the loop wire properly, place it on the terminal board and tighten securely with the
terminal screw using a screwdriver.
(2). For strand wiring (Fig. 4.36)
1). Cut the wire end with a wire cutter or wire-cutting pliers, then strip the insulation about 10
mm (3/8inch) .
2). Using a screwdriver, remove the terminal screw (s) on the terminal board.
3). Using a round terminal fastener or pliers, securely clamp a round terminal to each stripped
wire end.
4). Position the round terminal wire, and replace and tighten the terminal screw with a
screwdriver.(Fig. 4.37)
25mm (15/16inch)
10mm(3/8inch)
Fig. 4.36
Fig. 4.37 Fig. 4.38