Use and Care Manual

5
3.2 Selection of the Installation Location
The outdoor unit must be installed on a mounting pad which can withstand the weight of the unit.
Otherwise, the unit may fall off and cause damage.
Do not install the unit at a place where combustible gas is stored.
Do not install the unit near heat source , steam, or ammable gas.
Decide the installation location with the customer as follows:
3.2.1 Indoor Unit
Select an installation site where the following conditions are fulfilled and that meets your
customer’s requirement.
(1). Obstruction should be removed from air inlet and air outlet of the indoor unit so that the
airow can reach every corner of the room.
(2). Make sure that the installation meets the minimum installation clearance dimensions.
(3).
Select a ceiling support that can withstand 4 times of the weight of the indoor unit and would not
increase the operating noise and vibration of the unit.
(4). Select a location where a level installation is guaranteed.
(5). Select the place where it's easy to drain out the condensate water, and connect with outdoor
unit.
(6). Make sure that there is enough space for care and maintenance, and the height
between the indoor unit and floor is a minimum 6 feet.
(7). When installing the suspension bolt, check if the installation location can support 4 times of the
weight of the unit. If not, reinforce it before starting the installation.
Note: Kitchen and dining room installations may have reduce capacity
over time due to grease and dirt accumulation on indoor fan and coil.
>20(3/4)
≥1500(59)
≥1500(59)
Unit: mm
≥2500(72)
Models
H
mm(inch)
255(10)
260(10-1/4)
340(13-3/8)
340(13-3/8)
340(13-3/8)
320(12-5/8)
Table 3.3
Fig.3.1
Unit: mm(inch)
UMAT18HP23 0V1AC
UMAT24HP23 0V1AC
UMAT30HP23 0V1AC
UMAT36HP23 0V1AC
UMAT42HP23 0V1AC
UMAT48HP23 0V1AC
U-match Series Cassette Type Unit
.
.
.
①
②
③