Service Manual

Table Of Contents
U-Match Series DC Inverter Service Manual
132
Disassembly of fan and motor
Remark: Make sure that the power supply is cut off before disassembling and protect all the parts during disassembly.
Step
Illustration
Handling Instruction
Disassembly of fan motor
Disassemble the fixing screws on the fan
components. (As is shown in graph, circle
represents 6 screws.)
Disassemble the fastening screws on the fan
and motor. Remove the fan. (As is shown in the
graph, box represents screws.)
Disassembly of evaporator
Remark: Make sure that the power supply is cut off and protect the copper tube and aluminum fin. If the time for disassembly
shall be long, put the copper tube under pressurized condition.
Step
Illustration
Handling Instruction
1. Disassembly of fixing
screws on the side panels
of evaporator
Disassemble the fastening screw connecting
left and right side panels on the evaporator and
the upper cover plate. (As is shown in the
arrows direction in graph.)
2. Disassemble fastening
screws connecting
evaporator valve
seal-plate and joint flange
Disassemble the fastening screws on the valve
seal-plate and remove the valve seal-plate.
Disassemble the fastening screws on the
evaporators’ joint flange. (As is shown in the
graph, box represents fastening screws on
seal-plates while circle the fastening screws on
joining flange.
3. Removal of evaporator
Remove the evaporator. Removed evaporator
is shown in the graph.