2.4 Cooling and Heating Data Sheet in Rated Frequency
Rated cooling
condition(°F) (DB/WB)
Model
Pressure of gas pipe
connecting indoor and
outdoor unit
Inlet and outlet pipe
temperature of heat
exchanger
Fan speed of
indoor unit
Fan speed of
outdoor unit
Compressor
revolution
(rps)
Indoor Outdoor P (PSIG) T1 (°F) T2 (°F)
80/66 95/- 30K 130~145 46.8 to 52.8 127 to 96.8 Super High High 46
80/66
95/- 36K
130~145
46.8 to 52.8 127 to 96.8
Super High High
37
Rated heating
condition(°F) (DB/WB)
Model
Pressure of gas pipe
connecting indoor and
outdoor unit
Inlet and outlet pipe
temperature of heat
exchanger
Fan speed of
indoor unit
Fan speed of
outdoor unit
Compressor
revolution
(rps)
Indoor Outdoor P (PSIG) T1 (°F) T2 (°F)
70/- 20/19 30K 507~550 134.4 to 102 36 to 39 Super High High 46
70/- 20/19 36K 507~550 134.4 to 102 36 to 39 Super High High 34
Instruction:
T1: Inlet and outlet pipe temperature of evaporator
T2: Inlet and outlet pipe temperature of condenser
P: Pressure at the side of big valve
Connection pipe length: 24.6ft.
Cooling:
Heating:
2.3 Noise Curve
30
40
50
60
LM
36K
30K
30K
HSH
Indoor fan motor rating speed
Noise/dB(A)
45
50
55
60
65
70
75
80
20 30 40 50 60 70 80 90 100
Compressor frequency(Hz)
Noise dB(A)
Indoor side noise Outdoor side noise