Specifications

GREEN ENERGY BATTERY Co.,LTD
Page 5 of 21
3.11
Operating Temperature
工作温度
Discharge:
–20+60(放电)
Charge:
0+45(充电)
Cells must be stored at 25.2V25.9V.
Over long storage periods cells should
be cycled every 90 days. The method is
to do a charge-discharge cycle with
standard method, the charge to 25.2V
25.9V.
电芯应在 25.2V25.9V 状态下储存。
过长时间储存的电芯应每隔 90 天用
标准方法适时地进行一次充放电循
环。
3.12
Storage
Temperature
储存温度
-20~45 3 month
Percentage of
recoverable capacity
no less than 80% of
the initial capacities
恢复容量不低于初
始容量的 80%
-20~28 1 year
3.13
Charger 充电器(Charger
optional 充电器可选)
Specification(规格):CLASS 2 BATTERY CHARGER
Input 输入: 2-pin, AC100-240V, 50/60Hz, 1.8A
Output 输出:DC Plug (5.5mm-2.1mm), DC 29.4V, 2.0A
3.14
Conversion Line of Battery
电池组转换线
Specification(规格):Length of wire is 500mm 线长 500 毫米
Port 1 端口 1:XT60H-M
Port 2 端口 2:CB CONNECTOR
3.15
Weight
重量
Approximate 1520g
3.16 Appearance
外观
Without distortion and leakage
无变形、电解液泄露
3.17
Standard Testing Condition
标准测试环境
Temperature(温度) 25±5
Humidity(湿度) : 75%RH
Atmospheric Pressure(大气压) 86-106 Kpa
Remark: 1.From3.1 to 3.17the testing condition is following 3.17standard testing condition)
3.1 3.17 目,测试环境遵从 3.17 标准测试环境)
2. If the working condition is out of 3.17, the performance will be some shift.
如果工作环境超出 3.17 围,性能将会有一些偏移。
4. Single Cell Performance Criteria 单电芯性能标准
4.1 Standard testing environment
标准测试环境
Unless specifically stated otherwise, tests must be done within one month of delivery and the
number of charging-recharging cycles is fewer than 5. The following is test conditions:
Test conditions: