Installation Sheet

1
October 2021
LUXURY RIGID CORE SPC FLOORING
Inspect ALL materials carefully BEFORE installation. Warranties DO NOT cover materials with visible defects once they
are installed.
It is the responsibility of the installer/owner to determine if the job site subfloor and job site conditions are environmentally
and structurally acceptable for Rigid Core floor installation. The flooring manufacturer declines any responsibility for floor
failure resulting from or connected with subfloor, subsurface, job site damage or deficiencies after hardwood flooring has
been installed.
CHECKLIST:
Flooring should only be installed in temperature-controlled environments. It is necessary to maintain a constant
temperature 48 Hours before, during and after the installation.
Store the packages in the future room climate and open package after package
This floor will be floating installed, i.e. always keep a minimum 1/4 distance to all walls and vertical obstructions. Do
not install cabinets on top of this product.
Check your subfloor, it must be dry (measure always!), clean, firm, and flat.
Measure the room and decide installation direction. Note the limitations as per below
Transition are required only if installing in a room or area that is larger than 100 lineal ft. in any direction.
Radiant Heat see IN-FLOOR RADIANT HEAT and requirements below.
Check your floor continuously during the installation. Defective boards that are installed are not covered by warranty
To preserve your floor, clean and maintain your floor correctly.
Tools for Installation:
Utility Knife, Straight Edge, Measuring Tape, ¼" Spacers, Pencils, Eye Protection, Soft-Faced Rubber Mallet ,Broom,
Felt Pads, Tapping Block, Pull Bar, Level
Optional: Carpenter’s Square, Jig Saw, Table Saw, Miter Saw, Circular Saw, Hole Saw, Moisture Meter (wood, concrete,
or both). Power tools can be dangerous, operate in strict accordance with manufacturer’s operating instructions and
safety precautions.
GENERAL REQUIREMENTS (ALL SUBFLOORS):
Must be flat to within 3/16 in a 10ft radius; no bumps or low spots. Subfloors should not slope more than 1" per 6ft.
Must be clean: no construction debris, soil, mud or any other objects on or adhering to the floor. If necessary, scrape
and sweep away before the installation; no protrusions of nails, debris, or metals should remain.
Must be free from moisture-related conditions that can damage the installed flooring.
Be structurally sound without deflection.
DO NOT install material over wood subfloors that lay directly on concrete or over sleeper construction.
Important Information:
You should allow for 5%-10% more flooring than square footage to account for cuttings and waste
When installing the subfloor flatness tolerances should be no more than 3/16” in 10 ft. Radius and there should be no
abrupt height differences. High spots should be sanded or ground down and low areas should be filled.
Over concrete subfloors we recommend using 6 mil polyfilm moisture barrier.
If excessive moisture, over 85% RH, is present or if slab moisture cannot be verified, the use of a 6 mil polyfilm
moisture barrier is required. The moisture barrier should be overlapped six inches and taped at the seams.
Rigid Flooring includes a pre-attached sound reduction pad therefore no underlayment is required.