Energy Guide
SAFETY DATA SHEET
Effective May 2015 Page 4 of 10 MS-6.4-061 Rev B
US GreenFiber LLC
Conditions for safe storage, including any incompatibilities:
• Storage Temperature: Ambient
• Storage Pressure: Atmospheric
• Special Sensitivity: None
Control parameters:
This product is listed/regulated by OSHA and Cal/OSHA as “Particulates Not Otherwise
Regulated” or “Nuisance Dust.” This product is list by ACGIH as “Particulates Not Otherwise
Specified.”
COMPONENT/C
AS #
EXPOSURE LIMITS
Newsprint
(Cellulose Fiber)
#65996-61-4
OSHA PEL-TWA=15mg/m
3
total dust (PNOR)
PNOR - Particulates Not Otherwise Regulated or Nuisance
Dust
OSHA PEL-TWA=5mg/m
3
respirable fraction (PNOR)
Cal OSHA PEL=10mg/m
3
total dust (PNOR)
ACGIH TLV-TWA=10mg/m
3
inhalable (PNOS)
PNOS – Particulates Not Otherwise Specified
ACGIH TLV-TWA=3mg/m
3
respirable (PNOS)
Boric Acid
H
3
BO
3
#10043-35-3
OSHA PEL-TWA=15mg/m
3
total dust (PNOR)
OSHA PEL-TWA=5mg/m
3
respirable fraction (PNOR)
Cal OSHA PEL=5mg/m
3
ACGIH TLV-TWA=2mg/m
3
ACGIH TLV-STEL=6mg/m
3
(inhalable fraction – Borate
Compounds, inorganic)
Sodium
Polyborate
#183290-63-3
OSHA PEL-TWA=15mg/m
3
total dust (PNOR)
OSHA PEL-TWA=5mg/m
3
respirable fraction (PNOR)
Cal OSHA PEL=5mg/m
3
ACGIH TLV-TWA=2mg/m
3
Sodium
Tetraborate
Pentahydrate
#11130-12-4
OSHA PEL-TWA=15mg/m
3
total dust (PNOR)
OSHA PEL-TWA=5mg/m
3
respirable fraction (PNOR)
Cal OSHA PEL=5mg/m
3
total dust
ACGIH TLV-TWA=2mg/m
3
ACGIH TLV-STEL=6mg/m
3
(inhalable fraction – Borate
Compounds, inorganic)
Distillate Mineral
Oil
#8042-47-5
None (Oil mist exposure not applicable in finished product)
Appropriate engineering controls:
• General Exposure Controls: No specific controls are needed. Use standard good housekeeping
practices and engineering controls to minimize nuisance levels.
• Ventilation: Normal and adequate ventilation.
Individual protection measures, such as personal protective equipment:
SECTION 8 – EXPOSURE CONTROLS AND PERSONAL PROTECTION