SDS

Safety Data Sheet
According to HCS-2012 APPENDIX D TO §1910.1200
Version: 2.0/EN
Revision date: 2018.01.01
Product name: Lithium ion battery
Issue date: 2018.06.26
Report No.: NCT18024201S1-1 Page 5 of 10
TRF: SDS-V2 Effective Date : 2018-01-01
Always follow the warning information on the batteries and in the manuals of devices. Only use the recommended
battery types. Keep batteries away from children. For devices to be used by children, the battery casing should be
protected against unauthorized access. Unpacked batteries shall not lie about in bulk. In case of battery change
always replace all batteries by new ones of identical type and brand. Do not swallow batteries. Do not throw
batteries into water. Do not throw batteries into fire. Avoid deep discharge. Do not short-circuit batteries Use
recommended charging time and current.
(b) Conditions for safe storage, including any incompatibilities
If the battery is subject to storage for such a long term as more than 3 months, it is recommended to recharge the
battery periodically. And recommended at -10
~+45
for long period storage. Do not storage the battery
haphazardly in a box or drawer where they may short-circuit each other or be short-circuited by other metal objects.
Keep out of reach of children.
8. Exposure controls/personal protection
(a)Control parameters
Exposure Guidelines
Chemical Name
ACGIH TLV
OSHA PEL
NIOSH IDLH
Lithium Cobalt Oxide
(CoLiO2)
12190-79-3
TWA: 0.02 mg/m3
Graphite
7782-42-5
2 mg/m3 TWA
(Respirable fraction)
15 mppcf (Z-3)
2.5 mg/m3 TWA
Copper
7440-50-8
TWA: 0.2 mg/m3 fume
TWA: 1
mg/m3 Cu dust and mist
TWA: 0.1 mg/m3 fume
TWA: 1 mg/m3 dust and mist
(vacated) TWA: 0.1 mg/m3 Cu
dust, fume, mist
IDLH: 100 mg/m3 dust,
fume and mist
TWA: 1 mg/m3 dust
and mist
TWA: 0.1 mg/m3 fume
Aluminum
7429-90-5
TWA: 1 mg/m3
respirable fraction
TWA: 15 mg/m3 total dust
TWA: 5 mg/m3 respirable fraction
(vacated) TWA: 15 mg/m3 total
dust
(vacated) TWA: 5 mg/m3
respirable fraction (vacated)
TWA: 5 mg/m3 Al Aluminum
TWA: 10 mg/m3 total
dust
TWA: 5 mg/m3
respirable dust
Phosphate(1-),
hexafluoro-, lithium
21324-40-3
TWA: 2.5 mg/m3 F
TWA: 2.5 mg/m3 F
TWA: 2.5 mg/m3 dust
(vacated) TWA: 2.5 mg/m3