MAINTENANCE
• Reinstall the impeller pulley bracket with the three (3) screws.
• Reinstall the ange lock nut. Tighten the nut.
• Reinstall the belt cover with the ten (10) screws. In order to facilitate the installation,
position the narrow part of the cover into the recess of the housing and install the two top
screws, and then push the rest of the cover down into the recess and over the rotor shaft.
Tighten all ten (10) screws.
NOTE: If the ange lock nut is damaged, do not replace it with a standard nut. Use only the manufacturer's
original replacement parts.
W A R N I N G
When fitting the belt back into the main housing, verify that the belt is positioned to the right
of the Drive Belt Retainer. If the belt is positioned to the left of the Drive Belt Retainer, serious
damage may occur.
15
Fig. 8
Drive Pulley
Belt Tensioner
Impeller
Pulley
Washer
Belt