User manual

H42.1.01.6C-03 page 1 of 2
Operating manual for
moisture indicator for wood and buildings
GMI 15
Range of application:
This device is designed for quick-response measuring of moisture in buildings, on building sites etc..
The GMI15 allows moisture measurements in wood down to a depth of approx. 3 cm. and down to a depth of approx.
4 cm in concrete or wash floor. It is even able to detect moisture behind ceramic tiles or behind and under various floor or
wall coverings! Simply place device on top of the surface to be measured - no injection into the mearusing object required!
Specification:
Display: 3½-digit, 13mm high LCD-display
Power supply: 9V-battery (type IEC 6F22)
Power consumption: approx. 5mA
Low battery warning: automatic warning „BAT“ if battery is low
Working temperature: 0 to 50° C
rel. humidity: 0 to 80 % r. h. (non condensing)
Storage temperature: -20 to 70° C
Dimensions: impact resistant ABS housing,
106 x 67 x 30 mm (h x w x d).
Weight: approx. 150 g (ready for operation)
EMC: The GMI 15 corresponds to the essential
protection ratings established in the Regulations
of the Council for the Approximation of
Legislation for the member coutries regarding
electromagnetic compatibility (89/336/EWG).
Safety regulations:
This device has been designed and tested in accordance with the safety regulations for electronic devices.
However, its trouble-free operation and reliability cannot be guaranteed unless the standard safety measures and special
safety advises given in this manual will be adhered to when using the device.
1. Trouble-free operation and reliability of the device can only be guaranteed if the device is not subjected to any other
climatic conditions than those stated under "Specification".
2. If the device is transported from a cold to a warm environment condensation may result in a failure of the devcie. In such a
case make sure the device temperature has adjusted to the ambient temperature before trying a new start-up.
3. If there is a risk wahtsoever involved in running it, the device has to be switched off immediately and to be marked
accordingly to avoid re-starting.
Operator safety may be at risk if:
- there is visible damage to the device
- the device is not working as specified
- the device has been stored under unsuitable conditions for a longer time
In case of doubt, please return device to manufacturer for repair or maintenance.