H55.0.21.6C-02 Operating Manual Precision Barometer from Version 1.0 GPB 3300 GREISINGER electronic GmbH D - 93128 Regenstauf, Hans-Sachs-Straße 26 phone: +49 9402 / 9383-0, fax: +49 9402 / 9383-33, eMail: info@greisinger.
H55.0.21.6C-02 Operating Manual GPB 3300 _____________________________________________________ page 2 of 7 _____________________________________________________________________________ Content 1 INTENDED USE..........................................................................................................................................3 2 GENERAL ADVICE ...................................................................................................................................
H55.0.21.6C-02 Operating Manual GPB 3300 _____________________________________________________ page 3 of 7 _____________________________________________________________________________ 1 Intended use The device measures the absolute pressure of air or non corrosive / non ionizing gases. Relative measurements can also be realized via the integrated Zero-function. Field of application Barometric measurements (weather) Over- / Under- pressure measurements etc...
H55.0.21.6C-02 Operating Manual GPB 3300 _____________________________________________________ page 4 of 7 _____________________________________________________________________________ 5 Operation 5.1 Display elements 1: Main display Display of current measuring value or of minimal measured value (“Lo” blinking) or maximal value (“Hi” blinking) LOBAT Indicates low battery 5.
H55.0.21.6C-02 Operating Manual GPB 3300 _____________________________________________________ page 5 of 7 _____________________________________________________________________________ 10 Configuration of the device Follow these instruction to configure the functions of the device: Switch the device off. Press mode button and keep it pressed. Turn the device on. Release the mode button after the segment test ( ) finished. The first parameter “P.OFF“ is displayed.
H55.0.21.6C-02 Operating Manual GPB 3300 _____________________________________________________ page 6 of 7 _____________________________________________________________________________ 11 Adjusting of the instrument To adjust the instruments according to your needs proceed like follows: Switch instrument off. Press zero button and keep it pressed. Turn the device on. Release the mode button after the segment test ( ) finished. The first parameter “SCL” is displayed.
H55.0.21.6C-02 Operating Manual GPB 3300 _____________________________________________________ page 7 of 7 _____________________________________________________________________________ 14 Specification Measuring range air pressure: Measuring media Max. overload: Accuracy: (±1 digit) Pressure connection: Measuring frequency: Offset and scale: Min-/max-value memory: Sea level correction: 300.0 ... 1100.0 mbar abs., resolution: 0.1 mbar 225.0 ... 825.0 mmHg abs., resolution: 0.