H60.0.01.6C-11 Operating Manual Resistive material moisture measuring GMH 3810 as of version 1.5 with integrated measuring needles GREISINGER electronic GmbH Hans-Sachs-Str. 26 D-93128 Regenstauf Tel.: +49 9402 / 9383-0 Fax: +49 9402 / 9383-33 http://www.greisinger.de eMail: info@greisinger.
H60.0.01.6C-11 Operating Manual GMH3810 page 2 of 14 CONTENTS 1 IN GENERAL.............................................................................................................................................................................2 1.1 1.2 1.3 1.4 1.5 2 SAFETY INSTRUCTIONS .........................................................................................................................................................2 OPERATING AND MAINTENANCE ..................................
H60.0.01.6C-11 1.2 Operating Manual GMH3810 page 3 of 14 Operating And Maintenance • Battery The battery has been used up and needs to be replaced, if ! and „bAt“ are shown in lower display. The device will, however, continue operating correctly for a certain time. the battery has been completely used up, if ´bAt´ is shown in the upper display. The battery has to be removed, when storing device above 50°C.
H60.0.01.6C-11 Operating Manual GMH3810 page 4 of 14 2 Device Configuration For configuration of the device press "Menu"-key (key 4) for 2 seconds, the first menu will be shown. Choose between the individual values that can be set by pressing the "Menu"-key (key 4) again. The individual values are changed by pressing the keys "5" (key 2) or "6" (key 5). Use key "Store/↵ ↵" (key 6) to leave configuration and to store settings. 2.1 2.
H60.0.01.6C-11 Operating Manual GMH3810 page 5 of 14 Wet-Basis Moisture Content w (relative to total weight, mind the arrow at left bottom!) The wet-basis moisture content expresses the ratio of the mass of water to the total mass of the substance. The ratio is represented by the following equation (the unit is % as well): wet-basis moisture w[%] = (weightwet - weightdry) / weightwet *100 Or: wet-basis moisture w[%] = (weightwater) / weightwet *100 Example: 3.
H60.0.01.6C-11 Operating Manual GMH3810 page 6 of 14 Frequent sources of errors: - Attention with oven-dried wood: the moisture dispersion may be irregular, often in the core is more moisture than on the edge. - Surface-moisture: The wood-edge could be more humid than the core if the wood had been stored outside and e.g. was in rain. - Wood preservative and other treatment could falsify the measuring.
H60.0.01.6C-11 Operating Manual GMH3810 page 7 of 14 4 Hints For The Special Functions 4.1 Moisture estimation ('WET' - 'MEDIUM' - 'DRY') Additionally to the measuring value, an individual moisture estimation will be displayed simultaneously. This moisture estimation is only a guidance value, the final evaluation is depending on the application of the material. E.g.
H60.0.01.6C-11 Operating Manual GMH3810 page 8 of 14 7 Specification Measuring Channel1 Channel2 Principle Resistive material-moisture-measuring via integrated needles matching DIN EN 13183-2: 2002 Temperature-measuring via NTC Char. curve 466 different kinds of wood 28 different building materials Meas. range 0.0...100.0% moisture content (depending on characteristic curve) equal to ca. 3kOhm ... 2TerraOhm -30.0... +75.0°C / -22.0... + 167.0°F Resolution 0.1% moisture content 0.1°C / 0.
H60.0.01.6C-11 Operating Manual GMH3810 page 9 of 14 Appendix A: Sorts of wood Select kind of wood you want to measure, enter number on the device, e.g. birch = h. 60 Identification Group A Group B Group C Group D AS/NZS 1080.
H60.0.01.6C-11 Operating Manual GMH3810 Unknown) confertus Box, Brush (N.S.W.) Lophostemon confertus Lophostemon confertus Tristania laurina Xanthophyllum papuanum Planchonella pholmaniana Brachychiton carrthersii Bridelia minutiflora Box, Brush (Queensland Box, Kanuka Boxwood, New Guinea Boxwood, Yellow Brachychiton Bridelia Brigalow Brownbarrel Bubinga Buchanania Acacia harpohylla Eucalyptus fastigata Guibourtia demeusii Buchanania arborescens Dakua, Salusalu (Fiji) h.72 4..55% h.73 7..46% h.77 6.
H60.0.01.6C-11 River Hemlock / Hemlock, Western Hemlock, Chinesische Hevea Hickory Hollywood, Yellow Horizontal Incensewood Iroko Ironbark, Grey Ironbark, Grey Ironbark, Red Ironbark, Red, Broad Leaved Ironbark, Red, Narrow Leaved Jarrah Jelutong Jequitibá Operating Manual GMH3810 Tsuga heterophylla h.172 8..54% Tsuga chinensis h.173 h.174 h.175 h.176 Hevea Brasiliensis Carya spp.
H60.0.01.6C-11 Operating Manual GMH3810 Oak, Red Oak, Silky, Fishtail Oak, Silky, Northern Oak, Silky, Red Oak, Silky, Southern Oak, Silky, White Oak, Tasmanian Quercus spp, 5..91% Neorites kevediana 3..
H60.0.01.
H60.0.01.6C-11 Operating Manual GMH3810 page 14 of 14 Appendix B: Additional materials Select material you want to measure, enter number on the device, e.g. concrete b25 = b.