Use and Care Manual

-48-
Model G0857/G0858 (Mfd. Since 02/19)
8. Tighten outfeed table lock located so outfeed
table will not move during operation.
9. Re-install cutterhead guard, fence, and rear
access panel on stand.
10. Verify proper operation of cutterhead guard
(refer to Checking/Adjusting Cutterhead
Guard on Page 54 for instructions).
G0858
G0857
G0857
Figure 58. Knife or insert at TDC.
Top Dead
Center
Bottom Dead
Center
Top Dead
Center
G0858
Figure 59. Using straightedge to check outfeed
table height.
Straightedge
Outfeed Infeed
Straightedge
Outfeed Infeed
6. Use motor pulley to rotate cutterhead until
one knife or insert is at TDC (its highest point
during rotation), as shown in Figures 58–59.
7. Use outfeed table lever to set outfeed table
so knife or insert barely touches straightedge,
as shown in Figure 59.
Calibrating
1
8" Infeed
Table Stop
The infeed table on the Model G0857/G0858 has
a built-in table stop that automatically sets depth
of cut at
1
8". It is necessary to adjust this stop if
you adjust table parallelism.
Item(s) Needed: Qty
Precision Straightedge 3' .................................. 1
Tape Measure .................................................... 1
Hex Wrench 5mm .............................................. 1
To calibrate the
1
8" infeed table stop:
1. DISCONNECT MACHINE FROM POWER!
2. Remove table release knob by unthreading
it (see Figure 60), and then remove infeed
table covers (see Figure 60) by removing
plugs and cap screws that secure covers to
table.
Checking Adjusting 1/8 Infeed Table Stop
Figure 60. Accessing infeed table stop.
Table Cover
Access Holes
for Cap Screws
Knob Removed
from Stop