G0613/14 Swivel Mast Metal Cutting Bandsaw
-13-
Serious personal injury could occur if you
connect your machine to the power source
before you have completed the setup pro
-
cess. DO NOT connect the machine to the
power source until instructed to do so.
220V 3-Phase
(G0614)
Grounding
In the event of an electrical short, grounding
reduces the risk of electric shock. The grounding
wire in the power cord must be properly connect
-
ed to the grounding prong on the plug; likewise,
the outlet must be properly installed and ground
-
ed. All electrical connections must be made in
accordance with local codes and ordinances.
Electrocution or fire could
result if this machine is
not installed correctly or
the electrical installation
does not comply with local
and state codes. Ensure
compliance by using a
qualified electrician for the
electrical installation!
Extension Cords
We do not recommend using an extension cord
for the machine power supply. Instead, locate
your machine where you can eliminate the need
of an extension cord.
If you find it absolutely necessary to use an exten
-
sion cord, make sure the extension cord contains
a ground wire, and a grounding lug.
Use at least a 10 gauge cord that does not exceed
50 feet in length!
Amperage Draw
The Model G0614 features a 1 HP, 220V, 3-phase
motor that draws the following amps under maxi
-
mum load:
Motor Draw at 220V ............................... 3 Amps
Circuit Requirements
We recommend connecting your machine to a
dedicated and grounded circuit that is rated for
the amperage given below. Never replace a circuit
breaker on an existing circuit with one of higher
amperage without consulting a qualified electri
-
cian to ensure compliance with wiring codes
. If
you are unsure about the wiring codes in your
area or you plan to connect your machine to a
shared circuit, consult a qualified electrician.
220V 3-Phase Circuit ............................
15 Amps
Figure 5. NEMA L15-20R Plug and receptacle.