English Installation Mounting escutcheon, see Figs. [4] and [5]. 1. Remove the two screws (A1) and the adaptor (B) from the fitting template (A), then remove the template, see Fig. [1]. 1. Push sleeve (J) with the mark (J1) upward onto the mixer shank, make sure that the marking point (G1) snaps into the sleeve (J), see Fig. [4]. 2. Make sure the water supply is turned on at the service stop valves (C). Stop valves must be in fully open position (slots horizontal) for valve to function. 3.
7 D L D 100 °F (38 °C) 8 9 2mm O J M N M1 2mm O J1 P 2mm 5
English Adjustment Temperature setting, see Figs. [6] to [9]. • Before the mixer is put into service, if the mixed water temperature measured at the point of discharge varies from the specified temperature set on the thermostat handle. • After any maintenance operation on the thermoelement. 1. Push on adaptor (D) and grease O-ring, see Fig. [6]. 2. Open volume control (L) and measure the temperature of the water emerging with a thermometer, see Fig. [7]. 3.
10 O 11 O P M M 2mm N 12 13 KK H G2 G K1 K1 J 14 15 Q C Q2 16 Q1 S1 S R 34mm 77
English Maintenance Inspect and clean all parts, replace if necessary and grease with special valve grease. Thermostatic compact cartridge 1. Turn thermostat handle (M) to the 100 °F (38 °C) safety check, see Fig. [10]. 2. Unscrew handle (O) or lever (P). 3. Unscrew cap (N), see Fig. [11]. 4. Pull off thermostat handle (M). 5. Remove screws (K1) and escutcheon (K), see Fig. [12]. 6. Pull sleeve (J) from the mixer shank by pressing down the tongue (G2), see Fig. [13]. 7. Extract clamp (H). 8.
17 18 U U1 T1 V2 V1 T 19 U W 99 X
English Check valves 1. Same procedure as for thermostatic compact cartridge, steps 1-5. 2. Remove the four corner screws (T1) and remove the valve cover (T) as assembled unit with the O-ring (U1), see Fig. [17]. 3. Pull the cartridge holder (U) out of the valve body noting the location of "H" and "C". 4. Remove the check valve inserts (V1) or (V2), see Fig. [18]. If the check valves are removed it is important to reinstall them with the O-ring facing away from the cartridge.
D ✆ +49 571 3989 333 impressum@grohe.de A ✆ +43 1 68060 info-at@grohe.com AUS Argent Sydney ✆ +(02) 8394 5800 Argent Melbourne ✆ +(03) 9682 1231 B ✆ +32 16 230660 info.be@grohe.com BG ✆ +359 2 9719959 grohe-bulgaria@grohe.com CAU ✆ +99 412 497 09 74 info-az@grohe.com CDN ✆ +1 888 6447643 info@grohe.ca CH ✆ +41 448777300 info@grohe.ch CN ✆ +86 21 63758878 CY ✆ +357 22 465200 FIN ✆ +358 10 8201100 teknocalor@teknocalor.fi GB ✆ +44 871 200 3414 info-uk@grohe.