User manual
McGuard UP
WALL SWITCH
PRESENCE DETECTOR
INSTRUCTION MANUAL
Rated Voltage 220-240V~ 50 / 60Hz
Load
Incandescent Lamp : Max. 2000W
AC Halogen Lamp : Max. 1000W
LV Halogen Lamp : Max. 1000VA / 600W
(traditional)
Max. 1000VA / 900W
(electronic)
Fluorescent Lamp : Max. 900VA / 100μF
25 x (1 x 18W); 12 x (2 x 18W);
5 x (1 x 36W); 7 x (2 x 36W);
10 x (1 x 58W); 5 x (2 x 58W)
LED Lamp : Max. 400W
Energy Saving Lamp : Max. 600VA / 400W
(incl. CFL and PL Lampe)
Power Approx. 0,5W
consumption:
Detection 180° up to 8m forward und 6m each sideward
Range at hight of 1.2m
LUX Adjustable from approx. 10Lux to (∞) and
Adjustment “ ” (learning range: 10Lux - 2000Lux)
Auto Off Time Adjustable from approx. 10Sek to 30Min, and
Adjustment Test &
Mic. Sensitivity + (max.) / -(off)
TECHNICAL SPECIFICATIONS
1s
Operation Mode Manual ON / AUTO / Manual OFF
Operating Temperature 0C° bis +45C°
Environmental Protection IP40
TECHNICAL SPECIFICATIONS
Installation and assembly of electrical equipment
must be carried out by qualified electricians.
Contact a qualified electrician in the event of fault
or break down.
CAUTION!
- A circuit breaker (250VAC, 10A) type C according to EN60898-1 of load shall be
installed in the fixed wiring for protection.
- Do not mount on conductive surface.
- Do not open the enclosure frequently.
- Turn off power when change the light sources.
- High in-rush current would be caused when bulbs of certain brands burned which
might damage the unit permanently.
1 PACKAGE CONTENTS
Pattern
Item
Quantity
Detector
1
Lens shield label
1
Manual
1
2 PRODUCT DESCRIPTION
Der Mc Guard is an indoor wall switch presence detector, and is ideally to
be located in small-scaled stores or factories, offices, homes, at the places
such as corridors, staircase, archive rooms, cellars, rest rooms, play rooms,
garages, etc.
2.1 Features
- The stylish cosmetic design of integrating lens with front housing and
invisible knobs for restricting the liberty of unauthorized operation.
- Superior lens pattern and well distributed as well as concentrated
detecting beams provide high sensitivity.
- In addition to PIR sensing, the detector can be properly triggered by the
sound too.
- Excepting the provided Lux values, the ambient light level can be read-in
as the Lux value for more flexible application.
- Three practical operation modes (Manual ON / AUTO / Manual OFF)
available for user’s flexible application.
- The connected lighting can be manually switched on/off by connecting a
push button switch to the detector.
- The decorative Frame of 50 x 50 mm fits most European standard wall
switches.
2.2 Dimension
80 x 80 x 51,5mm (See FIG. 1)
FIG. 1
Bild 3
3.2.2 Manual on / off switching by using push button to activate R
terminal
An additional push button can be connected between terminal R and L
for manual on / off operation (case 1: on --> off; case 2: off -->on). While
pressing push button (≤1sec):
Case 1: Manual off switching (Lux settings is invalid):
Under the light on status, the light can be manually switched off by short
pressing ( 1sec) the push button. During this operation mode, once the
detector is triggered by movement, the light keeps off within the set switch
off delay time. Until there is no movement detected and the pre-set switch
off delay time has reached, the detector resumes to work according to the
previous operation mode set by knobs or IR. To press the push button
(≤1sec) during the light manual off period will activate the manual light on
function (working as the Case 2).
Case 2: Manual on switching (Lux settings is invalid): Under the light
off status, the light can be manually switched on by short pressing ( 1sec)
the push button. During this operation mode, once the detector is triggered
by movement, the light keeps on within the pre-set switch off delay time.
Until there is no movement detected and the pre-set switch off delay time
has elapsed, the detector resumes to work according to the previous
operation mode set by knobs or IR. To press the push button (≤1sec) during
the light manual on period will activate the manual light off function (working
as the Case 1).
3.2.3 Auto sensitivity adjustment function To raise the sensitivity of
detector after load is switched on can reduce the possibility of false-off
problem. When the load is on, the sensitivity of detector will be raised
automatically. When the load is off, the sensitivity of detector will return to
normal standby condition.
3.2.4 Acoustic control function
By setting the Mic. knob to “+” position, this function is enabled. This
function is only available when detector works in auto mode and the
detector is activated by movement at first, then the acoustic sensor control
function is workable. Once the detector is firstly triggered by movement to
turn on the load, then within 8sec, the acoustic sensor is used as an
auxiliary sensor to be activated by sound in order to renew the delay off
time and to continuously switch on the load. If there is no sound detected
within 8sec. after the first triggering by movement, the acoustic sensor is
ineffective.
3.3 Wiring
3.3.1 Normal operation (See FIG.5)
3.3.3 One detector controls staircase time switch (Time knob sets at )
(See FIG.7)
1s
FIG. 5
FIG. 7
Bild 2
3.3.2 Two detectors control a load (See FIG.6)
3.2 Function
3.2.1 Ambient light appraisal
According to the changeable ambient light level, detector can postpone
delay time of switching light on and off to avoid unnecessarily switching due
to rapid ambient light change:
Ambient light level changes from bright to dark:
If the ambient light level keeps be lower than the preset Lux value for
10sec, the light will be automatically switched on after 10sec. (LED will be
on 10sec for indication).
Ambient light level changes from dark to bright:
If the ambient light level continuously exceeds the switch off Lux value for
5min, there are different reactions according to the time setting value.
Time setting ≥ 5min, the light will be automatically switched off after 5min.
Time setting < 5min, the light will be automatically switched off when the set
time reached if no movement is detected during the 5min. But if there is
movement detected within the 5min, the time will be reset upon detection
and until 5min later, the light is switched off.
3.1.3 Helpful tips for installation
Since the detector is in response to temperature change, the
following conditions should be avoided (See FIG.4-A & FIG.4-B):
- Avoid aiming the detector toward the objects which may be swayed in the
wind, such as curtain, tall plants, miniature garden, etc.
- Avoid aiming the detector toward the objects whose surfaces are highly
reflective, such as mirror, monitor, etc.
- Avoid mounting the detector near heat sources, such as heating vents, air
conditioning, vents as dryers, lights, etc.
3.1.2 Pay attention to the walking direction in the test proceeding. It is more
sensitive to movement across the detector and less sensitive to
movement directly toward to detector which will reduce the detection
coverage (See FIG.3).
3 INSTALLATION AND WIRING
Please disconnect power completely and read the
entire instruction manual carefully before installation.
3.1 Select a proper location
3.1.1 Detection coverage
It is recommended to install at the height of 0.8m - 1.5m. The forward
detection distance can reach up to 8m and 180 detection angle (See
FIG.2).
Side view
Top view
Top view
Side view
GB
FIG. 4-B
FIG 4-A
N
L
Taster
Last
N
L
Push button
Load
Push button
FIG. 6
Staircase time switch
N
L
Push button
Load
Push button