User Manual

6 7 8
1
2
3
4
5
6
1
2
3
4
Repeat the above steps as necessary in order to ensure that the
vibration is recognised correctly. If you were not able to set the
correct sensitivity then please move the vibration sensor.
LCD display when synchronisation is correct
The device is ready for operation
The device is in idle mode (no vibration was detected)
NOTE
The recognition interval for the vibration sensor during
operation depends on the set lubricant capacity.
60/125 ml: Interval length 15 minutes
250 ml: Interval length 30 minutes
User manual
G-LUBE VIB 60, 125, 250
Screw o the top section and
the empty cartridge. Change
the battery and secure it with
the clip.
Press the cartridge lightly so
that some lubricant escapes.
Screw in the cartridge without
overtightening it.
Mount the top section until it
clicks.
Attach the included sticker to
the drive unit and write the
installation date and expiry date
on it.
Pull the dust protection cover
over the lubricant dispenser
where necessary.
6. Mounting
Direct mounting is always preferred.
If the application does not allow direct mounting, remotely assemble the
unit using appropriate accessories and keep the distance from the lube
point as short as possible.
For remote installations use a 6 mm (outer diameter) tube pre-lled
with the same or compatible grease as the grease contained in the unit.
Multiple point installation is possible using a
progressive distributor. Do not block any connec
-
tions to the progressive distributor. Instead use
a suitable distributor in accordance with the
number of lubrication points. Keep the distance
between the distributor and the lubrication unit
as short as possible.
7. Important information
The lubricant dispenser is not suitable for use with oil.
Minimize tube resistances. Narrow passages and right angles
should be avoided.
The cable on the vibration sensor may not touch the vibrating
machine.
During operation of the device a visual inspection of the device as
well as of the lubrication point must be carried out regularly. The
calibration of the sensor must be repeated at periodic maintenance
checks in order to ensure that the vibration is correctly recognised.
Product warranty is limited to original defects in material and
workmanship and does not cover any collateral damage due to
mishandling, abuse and/or any other inappropriate use of the
device.
The maximum storage temperature should not exceed +40 °C
(+104 °F). Higher temperatures decrease the battery‘s lifespan.
The lubricator has to be activated within two years from receiving.
If the LCD displays
after 2 years from the installation date
(1.5 years for 250 ml) please replace the battery and the cartridge
immediately. Dosing errors can occur after using the device for too
long because of grease hardening or a reduction in battery charge.
Open the protective cap on
the vibration sensor.
Hold POWER pressed down
and press MODE in order to
start the vibration recognition
mode. This takes 60 seconds.
Use a screwdriver to set
the wheel to 0 (10=factory
setting/highest sensitivity).
Turn the wheel slowly in a
clockwise direction until the
clock symbol ashes and the
red LED ickers.
8. Changing the cartridge5. Calibrate vibration sensor