GRUNDFOS INSTRUCTIONS JP PS Jet pumps with pressure switch, 115/230 V, 60 Hz Installation and operating instructions
English (US) Installation and operating instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
English (US) English (US) Installation and operating instructions Original installation and operating instructions Table of contents 1. Limited warranty . . . . . . . . . . . . . . . . . . . . . . . . . . 4 2. 2.1 2.2 2.3 General information Target group. . . . . . Hazard statements . . Notes . . . . . . . . . . 3. 3.1 3.2 Receiving the product . . . . . . . . . . . . . . . . . . . . . . . 5 Inspecting the product. . . . . . . . . . . . . . . . . . . . . . . . 5 Scope of delivery . . . . . . . . . .
SIGNAL WORD Description of the hazard Consequence of ignoring the warning • Action to avoid the hazard. 4. Installing the product English (US) The hazard statements are structured in the following way: 4.1 Location The product can be installed both indoors and outdoors. Use a suitable cover to protect the product from direct sunlight, rain or snow. Please observe the following: 2.
4.2.2 Connecting the pipe system WARNING Install the product so that it is not stressed by the pipe system. Electric shock Death or serious personal injury ‐ Switch off the power supply before you start any work on the product.Make sure that the power supply cannot be switched on accidentally. Pipe dimensions: • The diameter of the inlet pipe must be larger than 1 inch, if the inlet pipe is longer than 32.8 ft (10 m), or if the suction lift exceeds 13.1 ft (4 m).
English (US) 4.2.2.1 Maximum system pressure Make sure that the system in which the pump is installed is designed for the maximum pump pressure. TM058227 The maximum inlet pressure depends on the feet of head at the actual duty point. The sum of the inlet pressure and the feet of head must not exceed the maximum system pressure. We recommend installing a pressure-relief valve to protect the pump so that the outlet pressure does not exceed the maximum system pressure. Related information 10.
We recommend that you follow the installation examples. Valves are not supplied with the pump. 4.2.3.1 Suction from a tank 7 4 3 4 1 1 2 5 3 2 3 7 5 6 Pos. Description 6 Pos. Description Highest faucet 1 Highest faucet 2 Isolating valve 2 Isolating valve 3 Pipe support 3 Pipe support 4 Pressure tank 4 Pressure tank 5 Drain to sewer 5 Slight downward slope 6 Strainer. A foot valve is optional. We recommend using a foot valve together with JP PS. 6 Foot valve with strainer.
4.3.2 Connecting to the power supply WARNING WARNING Electric shock Death or serious personal injury ‐ Switch off the power supply before you start any work on the product. Make sure that the power supply cannot be switched on accidentally. Electric shock Death or serious personal injury ‐ Disconnect the main switch prior to electrical work. ‐ Assume all wires are live. Use an electrical tester to confirm the power is off at each wire.
Follow these steps to connect a power cable to the product: 1. Loosen the nut on the top cover of the pressure switch. 2. Lift up the pressure switch cover and set it aside. 3. Inside the pressure switch, gently push aside the factory wires. Do not disconnect them. 4. Locate the open knockout in the metal plate inside the pressure switch. 5. In the knockout, install a clamp-type fitting designed for connecting a power cable. 6. Loosen the screws on the clamp. 7.
English (US) 4.3.2.3 Connecting to residential hard wiring, 115 or 230 V For residential hard wiring, use the following: Pump model Recommended cable type JP PS, all models, 115 V or 230 V SJOW 12AWGx3 UL Follow these steps to connect the the product to the power supply: 1. Loosen the nut on the top cover of the pressure switch. 2. Lift up the pressure switch cover and set it aside. 3. Inside the pressure switch, gently push aside the factory wires. Do not disconnect them. 4.
4 M1 M2 L2 PS L1 4 2 M1 M2 2 1 3 G2 G1 1 3 G2 Pos. Description Pos.
4 M1 M2 L2 PS L1 4 2 M1 M2 L2 PS 2 1 3 G2 G1 TM074151 1 3 G2 Pos. Description Pos.
English (US) 4.3.3 Setting the voltage converter WARNING Electric shock Death or serious personal injury ‐ Do not pull the voltage switching plug by the wires. To avoid damage, only use a firm hand grip around the voltage switching plug. 1. Check the voltage indicated on the side of the voltage converter. 2. Turn the indicator so that the desired voltage (115 V or 230 V) points towards the side with the "M" lock catch. 3.
5.1 Priming the product English (US) 5. Startup of the product WARNING Electric shock Death or serious personal injury ‐ Do not use the product for cleaning and other maintenance of swimming pools or similar places if there are people in the water. CAUTION Always tighten the priming plug by hand. 1. Unscrew the priming plug. 2. Fill the pump with water. 3. Refit the priming plug and tighten by hand.
Pos. Description After installing the product, do the following: 5 Base plate 1. Open all isolating valves. Make sure that the water supply is sufficient on the inlet side of the pump. 6 Drain plug 2. Turn on the power supply to the pump, and the pump will start. If there is a suction lift, it can take up to five minutes before the pump delivers water. This period depends on the length and diameter of the inlet pipe. 7 Inlet connection, 1" NPT 3.
6.3 Identification 6.3.1 Nameplate example for JP PS Example: JP PS 18-05-154 1x115/230V 60 Hz Conduit XX TM074087 PS 18 04 154 Fig. English (US) 6.3.2 Type key, JP PS Type designation Description JP Jet pump PS Pressure switch 18 Nominal flow rate [US gpm] 05 Horsepower [Hp] 154 Max. head [ft] 1x115/230V Dual voltage (115 or 230 V) 60 Hz Frequency [Hz] Conduit Type of power connection XX Country of origin (Example: HU (Hungary) Nameplate, JP PS Pos.
WARNING Electric shock Death or serious personal injury ‐ Switch off the power supply before you start any work on the product. Make sure that the power supply cannot be switched on accidentally. 8.1 Draining the pump To drain the JP PS pump: 1. Unscrew the drain plug using a screwdriver. 2. Let the water flow out of the pump. 3. When the pump is empty, refit the plug by hand. 1 WARNING Chemical hazard Death or serious personal injury ‐ Make sure that the product has only been used for water.
9.3 The motor turns with difficulty 9.1 The motor does not start and makes no noise Cause Insufficient voltage or blockage Cause Power supply failure Remedy • Check the voltage which may be insufficient. Correct any errors. Remedy • Check the electrical connections. If the fault is repeated immediately, this means the motor is short circuiting. • Check whether any moving parts are scraping against fixed parts. Eliminate the cause of the scraping. • Check that the motor is live.
English (US) 9.7 The pump supplies insufficient flow Cause Insufficient intake due to blockage or worn parts Remedy • Blocked foot valve. Clean the foot valve. • The impeller is blocked or worn. Remove the blockage or replace the worn parts. • The diameter of the intake pipe is insufficient. Replace it with a larger diameter pipe. 9.
10.1 Operating conditions System pressure Max. 87 psi (6 bar / 0.60 MPa) Suction lift Max. 26.25 ft (8 m), including inlet-pipe pressure loss at a liquid temperature of 68 °F (20 °C) Liquid temperature Max. 104 °F (40 °C) (S1 mode*) / 140 °F (60 °C) (S3 mode**) Ambient temperature Max. 104 °F (40 °C) (S1 mode*) / 131 °F (55 °C) (S3 mode**) Relative humidity Max. 98 % Enclosure class IP44 Insulation class F Supply voltage 1 x 115 V, 60 Hz 1 x 230 V, 60 Hz 10.
Grundfos companies U.S.A. GRUNDFOS Pumps Corporation 9300 Loiret Boulevard Lenexa, Kansas 66219 USA Tel.: +1 913 227 3400 Fax: +1 913 227 3500 GRUNDFOS Water Utility Inc. 3905 Enterprise Court P.O. Box 6620 Aurora, IL 60598-0620 Phone: +1-630-236-5500 Fax: +1-630-236-5511 GRUNDFOS CBS Inc. 902 Koomey Road Brookshire, TX 77423 USA Phone: 281-994-2700 Toll Free: 1-800-955-5847 Fax: 1-800-945-4777 Peerless Pump 2005 Dr. Martin Luther King Jr US-46202 Indianapolis, Indiana U.S.A.