Product Manual
Table Of Contents
- English (US)
- 1. Limited warranty
- 2. General information
- 3. Receiving the product
- 4. Installing the product
- 5. Startup of the product
- 6. Product introduction
- 7. Service
- 8. Taking the product out of operation
- 9. Troubleshooting
- 9.1 The motor does not start and makes no noise
- 9.2 The motor does not start but makes noise
- 9.3 The motor turns with difficulty
- 9.4 The motor does not stop when the demand for water has ceased
- 9.5 The pump does not deliver water
- 9.6 The pump does not prime
- 9.7 The pump supplies insufficient flow
- 9.8 The pump vibrates and operates noisily
- 9.9 The pump stops unexpectedly during operation and starts again after a while
- 9.10 The pressure switch starts and stops frequently during normal water delivery
- 10. Technical data
- 11. Disposing of the product
4.3.2.4 Wiring diagram, pressure switch to 115 V power cable
M2
L2
L1
M1
G2
G1
1
PS
3
2
4
TM074151
Pos. Description
PS Pressure switch
1 Power cable (in)
2 To motor (out)
3 Motor
4 Capacitor
From power cable to pressure switch
G1 Green (ground)
L1 Black (live)
L2 White (neutral)
From pressure switch to motor
G2 Yellow (ground)
M1 Brown (live)
M2 Blue (neutral)
Related information
4.3.2.2 Connecting a 115 or 230 V power cable
4.3.2.5 Wiring diagram, pressure switch to 230 V power cable
M2
L2
L1
M1
G2
G1
1
PS
3
2
4
TM074151
Pos. Description
PS Pressure switch
1 Power cable (in)
2 To motor (out)
3 Motor
4 Capacitor
From power cable to pressure switch
G1 Green (ground)
L1 Black (live)
L2 Red (live)
From pressure switch to motor
G2 Yellow (ground)
M1 Brown (live)
M2 Blue (neutral)