Product Guide

Table Of Contents
Solar panel wiring
SQFlex
4
24
Now add the two pairs in parallel. Remember in
parallel, voltage remains the same and amperage
adds. Each pair produces 140V, so total voltage =
140V. Each pair produces 1.43A, so total amperage
is 1.43 + 1.43 = 2.86A. Watts always add, so
100W x 4 = 400W.
Cable sizing chart
Since the SQFlex motor operates at peak efficiency
with 120V or greater applied, we strongly recommend
configuring panels to achieve 120V or greater.
Lower voltages result in greater losses in the drop
cable, and it is important to the customer to make
efficient use of every watt generated. Additionally,
significant savings in drop cable costs can be realized
by configuring for higher voltages.
Notes:
Max. cable length in ft; uses a max. 3 % voltage drop.
Based on the Grundfos GF100 panel.
Max. cable length between CU200 and SQFlex = 650 ft (198 m).
Panels
Power
(Wp)
Voltage
(Vmp)
14
AWG
12
AWG
10
AWG
Amps
[Imp]
Series Parallel
1 100 70 290 461 733 1.4 1
2 200 140 580 922 1466 1.4 2
3 300 210 871 1383 2199 1.4 3
4 400 280 1161 1844 2932 1.4 4
6 600 210 435 692 1099 2.9 3 2
6 600 140 193 307 489 4.3 2 3
8 800 280 580 922 1466 2.9 4 2
8 800 140 145 231 366 5.7 2 4
9 900 210 290 461 733 4.3 3 3
10 1000 140 116 184 293 7.1 2 5
12 1200 280 387 615 977 4.3 4 3
15 1500 210 174 277 440 7.1 3 5
16 1600 280 290 461 733 5.7 4 4
18 1800 210 145 231 366 8.6 3 6
20 2000 140 58 92 147 14.3 2 10