34
CU 200 SQFlex control unit
IO 50 SQFlex switch box
IO 101 SQFlex switch box
IO 102 SQFlex breaker box
Charge controller
Voltage
30-300 VDC, 8.4 A.
90-240 VAC, 8.4 A.
Power consumption 5 W.
Current consumption Maximum 130 mA.
Pump cable
Maximum length between the CU 200 and the pump: 650 ft.
Maximum length between the CU 200 and the level switch: 2000 ft.
Back-up fuse Maximum 10 A.
Radio noise
The CU 200 complies with the EMC Directive 89/336/EEC.
Approved according to the standards EN 55014 and 55014-2.
Relative air humidity 95 %.
Enclosure class IP 55.
Ambient temperature
During operation: –22 °F to +122 °F (–30 °C to +50 °C).
During storage: –22 °F to +140 °F (–30 °C to 60 °C).
Marking CE.
Weight 4.5 lb.
Voltage
Maximum 300 VDC, 8.4 A.
Maximum 265 VAC, 8.4 A.
Enclosure class IP 66.
Ambient temperature
During operation: –22 °F to +122 °F (–30 °C to 50 °C).
During storage: –22 °F to +140 °F (–30 °C to 60 °C).
Marking CE.
Voltage
**115 VAC –15 % / +10 %, 50/60 Hz (internal relay).
Maximum 225 VDC, 8.4 A.
Maximum 115 VAC, 8.4 A.
** 230 VAC –15 % / +10 %, 50/60 Hz (internal relay).
Maximum 225 VDC, 7 A.
Maximum 265 VAC, 7 A.
Enclosure class IP 55.
Ambient temperature
During operation: –22 °F to +122 °F (–30 °C to 50 °C).
During storage: –22 °F to +140 °F (–30 °C to 60 °C).
Marking CE.
Voltage
Maximum 225 VDC, 8.4 A.
Maximum 265 VAC, 8.4 A.
Enclosure class IP 55.
Ambient temperature
During operation: –22 °F to +122 °F (–30 °C to 50 °C).
During storage: –22 °F to +140 °F (–30 °C to 60 °C).
Marking CE.
Voltage (solar input) Maximum 110 VDC.
Current (solar input) Maximum 15 A.
Output current (load) Maximum 15 A.
Ambient temperature –40 °F to +140 °F (–40 °C to +60 °C).