SQFlex Service Instructions

11 / 60
8. CU 200 indicates
‘F4 = overload’.
Too low input voltage.
Increase the supply voltage, to 30 VDC or
higher.
Pump is defective.
Repair or replace the pump.
Only helical rotor
pumps. Pumped liquid is
contaminated with oil or
similar substance.
Clean the liquid and replace the pump.
Motor liquid low / Missing.
Check or refill motor liquid.
9. Green indicator light
in ON/OFF button is
flashing.
Insufficient power supply.
Increase the number of solar modules or con-
nect an alternative energy supply, such as wind
turbine, batteries or generator.
Pump has seized up.
Clean the pump.
10.Running light on CU
200 but low wattage.
System not grounded.
Check system for adequate grounding
Pump is defective.
Repair or replace the pump.
If a centrifugal pump is used: Check that the riser
pipe is not blocked.
11. No light in front
cover. Pump delivers
water.
CU 200 is defective.
Replace the CU 200.
Ribbon cable not
mounted.
Mount the ribbon cable.
12.Pump does not stop
when water reservoir
is full.
Fault indicator light
on CU 200 is off.
Level switch is dirty or
defective.
Clean or replace the level switch.
Cable on level switch is
damaged.
Replace the cable.
13.Pump does not stop
when water reservoir
is full.
Fault indicator light
on CU 200 is on.
CU 200 is defective.
Replace the CU 200.
14.Pump does not start
when water reservoir
is empty.
Water reservoir indi-
cator is on.
Level switch is defective.
Replace the level switch.
Cable on level switch is
damaged.
Replace the cable.
CU 200 is defective.
Replace the CU 200.
Indication/Fault Possible cause Remedy