SQFlex Service Instructions

16 / 60
1.4.1 GF 80 solar modules
Visual inspection of solar modules
Check that the solar modules are intact.
Make sure that trees, grass, bushes, buildings, etc. do not cast a shadow on the solar modules.
Electrical connection GF 80 solar modules
Note: Before making any electrical connections, make sure that the solar modules are covered with a
non-transparent covering material to ensure that the modules are dead.
The cover must be removed before measuring is made.
Measurements must be made when the solar modules are not connected.
The current to be measured is the short-circuit current I
SC
.
The GF 80 solar modules are equipped with plugs and sockets for easy
connection of several modules in parallel or series. The solar modules must
be mounted on a support structure, tilted at an angle ensuring optimum
utilization of the solar energy.
This module is UL, Tüv, CE and IEC 61215 approved.
GF 80
Peak power (P
Max
)
80 W
Voltage (V
mp)
33.3 V
TM04 5085 2609
Current (I
mp
)
2.4 A
Open circut voltage (V
oc
)
41.5 V
Short circut current (I
sc
)
2.6 A
Reference cell temperature
(T
cref
)
25
°
C
Solar irradiation at reference
cell temperature (I
tref
)
1000
W/m
2