Brochure
0,5
1,5
1
2,5
2
3
P
2
[kW]
H [m]
η
[%]
10
30
20
50
40
60
70
80
4
4
8
12
16
20
24
28
32
36
40
8
12
16
20
ø260 mm
ø247 mm
ø234 mm
ø221 mm
Q (m
3
/h)
69
69
Figure 4.12 shows an example of the changed head and power curves for a
pump where the impeller diameter is machined to dierent radii in order to
match dierent motor sizes at the same speed. The curves are shown based
on formula (4.26).
Figure 4.12: Examples of curves for
machined impellers at the same speed but
dierent radii.