Overview of Primary Product
15
Technical data
VersaFlo UP, UPS
UPS 32-80
Electrical Data, Weights and Dimensions
NOTE: *460/575 volt models are two speed only - speeds 2 & 3
Technical Data
zzzzzzzzz
NPT 1/4
M
D5
D3
D2
D1
B7
B4
B5
L1
L3
D4
D6
D7
B2
B1
H2
H1
H3
Pump Type
Nomin
al HP at
Speed 3
PH
Suc.
Disc
Size
Volts
Dimensions [inches]
(mm)
Net Wt.
L1 L3 B1 B2 B4 B5 B7 H1 H2 H3 D1 D2 D3 D4 D6 D7
UPS32-80/2
1/2 1
1 1/4
(32)
115 or
230
11
(279)
5 1/2
(140)
5 5/16
(135)
5 9/16
(141)
3
(76)
3
(76)
3 3/16
(81)
2 11/16
(68)
9 7/16
(239)
12 1/16
(307)
1 7/16
(37)
2 9/16
(65)
3 7/16
(87)
4 5/8
(117)
1 13/16
(46)
2 1/4
(57)
39
1/2 3
1 1/4
(32)
208/230,
460*, 575*
11
(279)
5 1/2
(140)
5 5/16
(135)
5 9/16
(141)
3
(76)
3
(76)
3 3/16
(81)
2 11/16
(68)
9 7/16
(239)
12 1/16
(307)
1 7/16
(37)
2 9/16
(65)
3 7/16
(87)
4 5/8
(117)
1 13/16
(46)
2 1/4
(57)
39
Flow Range: 9-68 U.S. GPM Temperature Range (Open Systems): 14°F (-10°C) - 140°F* (60°C)
Head Range: 1-25 FEET Temperature Range (Closed Systems): 14°F (-10°C) - 230°F (110°C)
Maximum Working Pressure: 145 PSI Flanges: (NON ANSI)
1 1/4” 2 bolt with (2) 1/2” diam-
eter holes
Ambient Air Temperature 32°F (0°C) - 104°F (40°C)
MINIMUM INLET PRESSURE
Fluid Temperature
167°F (75°C) 194° (90°C) 230° (110°C)
1.6 Ft. - 0.7 PSI 11.8 Ft. - 5.1 PSI 55.2 Ft. - 23.9 PSI