Overview of Primary Product
25
Technical data
VersaFlo UP, UPS
UPS 40-160
Electrical Data, Weights and Dimensions
NOTE: *460/575 volt models are two speed only - speeds 2 & 3
Technical Data
zzzzzzzzz
Pump Type
Nomin
al HP at
Speed 3
PH
Suc.
Disc
Size
Volts
Dimensions [inches]
(mm)
Net Wt.
L1 L3 B1 B2 B4 B5 B7 H1 H2 H3 D1 D2 D3 D4 D6 D7
UPS40-160/2
3/4 1
1 1/2
(38)
115 or
230
11 1/2
(292)
5 3/4
(147)
5 3/4
(147)
6 5/8
(169)
3 15/16
(100)
3 15/16
(100)
3 3/16
(81)
2 15/16
(74)
9
(228)
11 5/8
(296)
1 11/16
(43)
2 7/8
(73)
3 7/8
(99)
5
(127)
2 1/16
(52)
2 9/16
(65)
50
3/4 3
1 1/2
(38)
208/230,
460*, 575*
11 1/2
(292)
5 3/4
(147)
5 3/4
(147)
6 5/8
(169)
3 15/16
(100)
3 15/16
(100)
3 3/16
(81)
2 15/16
(74)
9
(228)
11 5/8
(296)
1 11/16
(43)
2 7/8
(73)
3 7/8
(99)
5
(127)
2 1/16
(52)
2 9/16
(65)
50
NPT 1/4
M
D5
D3
D2
D1
B7
B4
B5
L1
L3
D4
D6
D7
B2
B1
H2
H1
H3
Flow Range: 20-117 U.S. GPM Temperature Range (Open Systems): 14°F (-10°C) - 140°F* (60°C)
Maximum Working Pressure: 145 PSI Temperature Range (Closed Systems): 14°F (-10°C) - 230°F (110°C)
Head Range: 1-46 FEET Flanges: (NON ANSI) 1 1/2”, 2-Bolt with (2) 1/2” dia. holes
Ambient Air Temperature: 32°F (0°C) to 104°F (40°C)
MINIMUM INLET PRESSURE
Fluid Temperature
167°F (75°C) 194° (90°C) 230° (110°C)
11.8 Ft. - 5.1 PSI 21.7 Ft. - 9.4 PSI 63.8 Ft. - 27.6 PSI