Overview of Primary Product

29
Technical data
VersaFlo UP, UPS
UPS 50-40
Electrical Data, Weights and Dimensions
NOTE: *460/575 volt models are two speed only - speeds 2 & 3
Technical Data
zzzzzzzzz
Pump Type
Nomin
al HP at
Speed 3
PH
Suc.
Disc
Size
Volts
Dimensions [inches]
(mm)
Net
Wt.
L1 L3 B1 B2 B4 B5 B7 H1 H2 H3 D1 D2 D3 D4 D6 D7
UPS50-40/4
1/3 1
2
(51)
115 or
230
14
(356)
7
(178)
5 5/16
(135)
5 9/16
(141)
3 9/16
(90)
3
(76)
4 3/4
(160)
3 1/4
(83)
10 1/8
(257)
13 1/8
(339)
2 1/8
(54)
3 7/16
(87)
4 1/16
(103)
5 1/4
(133)
2 1/2
(64)
3 1/16
(78)
54
1/3 3
2
(51)
208/230,
460*, 575*
14
(356)
7
(178)
5 5/16
(135)
5 9/16
(141)
3 9/16
(90)
3
(76)
4 3/4
(160)
3 1/4
(83)
10 1/8
(257)
13 1/8
(339)
2 1/8
(54)
3 7/16
(87)
4 1/16
(103)
5 1/4
(133)
2 1/2
(64)
3 1/16
(78)
54
B2
NPT 1/4
B1
H2
H1
H3
M
D5
D4
D3
D1
B7
B4
B5
L1
L3
D2
D6
D7
Flow Range: 20-122 U.S. GPM Temperature Range (Open Systems): 14°F (-10°C) - 140°F* (60°C)
Maximum Working Pressure: 145 PSI Temperature Range (Closed Systems): 14°F (-10°C) - 230°F (110°C)
Head Range: 0-12.5 FEET Flanges: (NON-ANSI) 2”, 4-Bolt with (4) 9/16” dia. holes
Ambient Air Temperature: 32°F (0°C) to 104°F (40°C)
MINIMUM INLET PRESSURE
Fluid Temperature
167°F (75°C) 194° (90°C) 230° (110°C)
1.6 Ft. - 0.7 PSI 6.7 Ft. - 2.9 PSI 50.4 Ft. - 21.8 PSI