Overview of Primary Product
35
UPS 50-160
Electrical Data, Weights and Dimensions
NOTE: *460/575 volt models are two speed only - speeds 2 & 3
Technical Data
zzzzzzzzz
Pump Type
Nomin
al HP at
Speed 3
PH
Suc.
Disc
Size
Volts
Dimensions [inches]
(mm)
Net
Wt.
L1 L3 B1 B2 B4 B5 B7 H1 H2 H3 D1 D2 D3 D4 D6 D7
UPS50-160/2
1 1/2 1
2
(51)
230
14
(356)
7
(178)
5 3/4
(146)
6 11/16
(170)
3 15/16
(100)
3 15/16
(100)
4 3/4
(121)
3
(76)
10 13/16
(274)
13 3/4
(349)
2 1/8
(54)
3 7/16
(87)
4 1/16
(103)
5 1/4
(133)
2 1/2
(64)
3 1/16
(78)
66
1 1/2 3
2
(51)
208/230,
460*, 575*
14
(356)
7
(178)
5 3/4
(146)
6 11/16
(170)
3 15/16
(100)
3 15/16
(100)
4 3/4
(121)
3
(76)
10 13/16
(274)
13 3/4
(349)
2 1/8
(54)
3 7/16
(87)
4 1/16
(103)
5 1/4
(133)
2 1/2
(64)
3 1/16
(78)
66
B2
NPT 1/4
B1
H2
H1
H3
M
D5
D4
D3
D1
B7
B4
B5
L1
L3
D2
D6
D7
Flow Range: 30-170 U.S. GPM Temperature Range (Open Systems): 14°F (-10°C) - 140°F* (60°C)
Maximum Working Pressure: 145 PSI Temperature Range (Closed Systems): 14°F (-10°C) - 230°F (110°C)
Head Range: 1-47 FEET Flanges: (NON-ANSI) 2”, 4-Bolt with (4) 9/16” dia. holes
Ambient Air Temperature: 32°F (0°C) to 104°F (40°C)
MINIMUM INLET PRESSURE
Fluid Temperature
167°F (75°C) 194° (90°C) 230° (110°C)
26.8 Ft. - 11.6 PSI 37 Ft. - 16.0 PSI 78.8 Ft. - 34.1 PSI
Technical data
VersaFlo UP, UPS