Overview of Primary Product
39
UPS 80-40
Electrical Data, Weights and Dimensions
NOTE: *460/575 volt models are two speed only - speeds 2 & 3
Technical Data
zzzzzzzzz
Pump Type
Nominal
HP at
Speed 3
PH
Suc.
Disc
Size
Volts
Dimensions [inches]
(mm)
Net
Wt.
L1 L3 B1 B2 B4 B5 B7 H1 H2 H3 D1 D2 D3 D4
UPS80-40/4 1/2 3
3
(76)
208/230
or 460*
19
(483)
9 1/2
(241)
5 3/4
(146)
6 11/16
(170)
5
(127)
3 15/16
(100)
6 5/16
(160)
3 13/16
(97)
9 7/16
(240)
13 1/8
(337)
3 3/16
(81)
5
(127)
6
(152)
7 9/16
(192)
95
B2
NPT 1/4
B1
H2
H1
H3
M
D5
D4
D3
D2
D1
B7
B4
B5
L1
L3
Flow Range: 30-190 U.S. GPM Temperature Range (Open Systems): 14°F (-10°C) - 140°F* (60°C)
Maximum Working Pressure: 145 PSI Temperature Range (Closed Systems): 14°F (-10°C) - 230°F (110°C)
Head Range: 1-13 FEET Flanges: (ANSI R.F.) 3”
Ambient Air Temperature: 32°F (0°C) to 104°F (40°C)
MINIMUM INLET PRESSURE
Fluid Temperature
167°F (75°C) 194° (90°C) 230° (110°C)
26.8 Ft. - 11.6 PSI 37 Ft. - 16.0 PSI 78.8 Ft. - 34.1 PSI
Technical data
VersaFlo UP, UPS