Brochure

Technical data
66
Approvals
Dimensions in inches unless o herwise noted.
TM03 5951 3806
0 10 20 30 40 50 60 70 80 90 100
Q[GPM]
0
4
8
12
16
20
24
28
32
36
40
[ft]
H
Flow range: 0-98 gpm
Head range: 0-37 feet
Motors: 2-pole, single-phase
Max. liquid temperature: 230 °F (110 °C)
Min. liquid temperature: 14 °F (–10 °C)
Max. system pressure: 145 psi (10 bar)
Closed system
Model Volts Amps Watts Hp Capacitor
UP 43-110 F
115 5.1 590 3/4 60μF
230 2.7 590 3/4 60μF
UP 43-110 F
TM02 0120 4301
D6
D2
D3
D7
D1
D4
D5
H1 H2
H3
NPT 1/4
B1
B2
B7
L1
B4 B5
L3
M
Model type
Product number
Connection type
and size
Shipping weight
[lbs]
115 V / 230 V
UP 43-110 F 96439643
GF 40/43 Flange
1 1/2”
41.2
Dimensions [inches]
L1 L3 B1 B2 B4 B5 B7 H1 H2 H3 D1 D2 D3 D4 D6 D7 M
8 1/2 4 1/4 5 1/4 5 9/16 2 15/16 2 15/16 3 1/8 2 5/8 9 5/8 12 3/16 1 5/8 2 15/16 3 7/16 4 3/4 2 1/16 2 1/2 12 mm
UP 43-110 F