UP/UPS Pumps Product Guide

Table Of Contents
Technical data
UP Series
6
68
UP 26-116 F/BF
Approvals
Note: Dimensions in inches unless otherwise noted.
TM03 5577 4412
0 4 8 12 16 20 24 28 32 Q [US GPM]
0
4
8
12
16
20
24
28
32
36
40
[ft]
H
0 1 2 3 4 5 6 7 8 Q [m³/h]
0
2
4
6
8
10
12
[m]
H
UP26-116F/BF
60 Hz
Flow range: 0-37 gpm (0-8.4 m
3
h)
Head range: 0-37 ft (0-11.3 m)
Motors: 2-pole, single-phase
Max. liquid temperature: 150 °F (65 °C)
Min. liquid temperature: 32 °F (0 °C)
Max. system pressure: 145 psi (10 bar)
Closed system (F) and open system (BF)
Model Volts Amps Watts Hp Capacitor
UP 26-116 F/BF 230 1.8 385 1/6 2.5 μF/380 V
UP 26-116 F/BF UP 26-116 BF
UP 26-116 F UP 26-116 BF
TM03 8758 2407
TM03 8543 1907
Model
Product
number
230 V
Dimensions [inches (mm)]
Connection type
and size
Shipping
weight
[lbs (kg)]
ABCDEF
UP 26-116 F 52722377 6.50 (165) 6.38 (162) 5.06 (129) 4.13 (105) 3.50 (89) 3.16 (80)
GF 15/26 flange
(2) 1/2" dia. bolt
holes
12.5 (5.7)
UP 26-116 BF 52722393 6.50 (165) 6.38 (162) 5.06 (129) 4.13 (105) 3.50 (89) 3.16 (80)
GF 15/26 flange
(2) 1/2" dia. bolt
holes
12.5 (5.7)