UP/UPS Pumps Product Guide

Table Of Contents
Technical data
UP Series
6
45
6. Technical data
UP 10-16 Comfort PM, PM Auto
UP 10-16 A/T/PM B5/BN5/BU
Approvals
Note: All models above have a 6 ft (1.8 m), 3-prong power cord.
Maximum external sensor cable length 8 ft (2.4 m).
UP 10-16 A PM BU/LC with integral check valve.
Dimensions in inches unless otherwise stated.
TM06 0178 4913
Flow range: 0 - 2.2 gpm (0 - 0.5 m
3
/h)
Head range: 0 - 3.9 ft (0 - 1.2 m)
Motor: Single-phase
Max. liquid temperature: 176 °F (80 °C)
Min. liquid temperature: 36 °F (2 °C)
Max. system pressure: 145 psi (10 bar)
Model Volts Amps Watts Hp Capacitor
UP 10-16 B5/
BN5/BU
115/208-230 V 0.23 6 0.008 -
Drinking Water System Components
In Accordance with NSF/A NSI 372
UP 10-16 PM B5, BN5
A/T/PM B5, BN5
UP 10-16 A PM BU
TM06 0649 0614
TM06 0684 0714
Model
Product
number
115/208-230 V
Dimensions [inches (mm)] Shipping
weight
[lbs (kg)]L1 H1 H2 H3 B1 B2 Connection
UP10-16 PM B5/LC 98420206 3.13 (79)
1.0 (25.4)
0.5 (12.7)
5.25 (133) 2.6 7 (68) 3.28 (83)
1/2" sweat 2.9 (1.3)
UP10-16 PM BN5/LC 98420210 3.13 (79) 0.5 (12.7) 1/2" NPT 3.4 (1.5)
UP10-16 A PM B5/LC 98420222 3.13 (79) 0.5 (12.7) 1/2" sweat 2.9 (1.3)
UP10-16 A PM BN5/LC 98420223 3.13 (79) 0.5 (12.7) 1/2" NPT 3.4 (1.5)
UP10-16 T PM B5/LC 99279870 3.13 (79) 0.5 (12.7) 1/2" NPT 3.4 (1.5)
UP10-16 A PM BU/LC 98420224 4.33 (110) 0.88 (23) 1 1/4" NPSM 3.8 (1.7)