UP/UPS Pumps Product Guide

Table Of Contents
Technical data
UP Series
6
46
UP 10-16 Comfort PM, PM Auto,
PM Temperature
The UP 10-16 pump is designed for recirculation of
domestic hot water in single-family homes with
dedicated hot-water return piping. Utilizing a low-noise
permanent magnet motor, energy consumption is
reduced to as little as 6 W. Selecting the Auto mode
ensures that the pump runs only when required. The
result is maximum comfort - no waiting for hot water
plus decreased water and power consumption.
Fig. 4 UP 10-16 APM BU/LC
Applications
Domestic hot-water recirculation systems in single-
family homes
small heating systems.
Pumped liquids
Domestic hot water
softened water
•clean water.
The pump uses two temperature sensors, one within
the pump and the other connected to the pump by a
cable installed on the hot-water flow pipe. The pump is
installed in the hot-water return pipe.
UP 10-16 A/T/PM pump with built-in temperature sensor
Three operating modes
100 % mode
The pump will operate 24/7/365 continuously at full
speed.
Temperature mode
The pump will keep the water temperature within an
automatically detected range.
Auto mode
The pump will learn, store and adapt operating
times to domestic hot water consumption patterns.
Disinfection and flushing
Once a week, a disinfection function is run for 15
minutes. If a higher temperature is measured at
another time of the week, the disinfection function
will run at this time.
After eight hours of no operation, the pump
automatically flushes the circulation pipe for 15
minutes.
Vacation feature
If no tappings are detected within a 24-hour period, the
pump will automatically switch to standby mode
(except for disinfection) and reactivate to the same
consumptive pattern when two tappings occur within a
20-minute time period (self-modulation).
Motor
The motor has a single-phase, 12-pole, permanent-
magnet design and is double insulated. No additional
motor protection is required.
Maximum system pressure
145 psi (10 bar).
Ambient and liquid temperatures
The ambient temperature must always be lower than
the liquid temperature as otherwise condensation may
otherwise form in the stator housing.
Liquid temperature: 36 °F (2 °C) to 176 °F (80 °C).
We recommend that you keep the operating
temperature as low as possible (e.g. 140 °F (60 °C)) to
avoid calcium precipitation.
TM06 0034 4713TM06 1073 1514
8-20 inches
Max. 8 ft.
Voltage 1 x 115/208-230 V, 50/60 Hz
Power 5 - 8.5 watts
Enclosure class IP42, type PM: IP44
Insulation class F
Description Material
Stator housing Aluminium
Spherical separator Stainless steel
Rotor can, complete Stainless steel/Tungsten carbide
Rotor, impeller Stainless steel, EPDM, PPO, PFTE, graphite
Pump housing EcoBrass
Gate valve EcoBrass
Screw Stainless steel
Terminal box cover PC/ABS
Motor cover PPO
Power cable jacket PVC
O-rings EPDM
Check valve POM
Light Lexan
Insulation cover EPP 55
External sensor cable PC/ABS