UP/UPS Pumps Product Guide

Table Of Contents
Technical data
UP Series
6
58
UP 15 MixiMizer™
UP 15-42 BUC5/BUC7/MR
Approvals
MixiMizer models include the following features:
Two water temperature sensors (supply and return
pipe) prewired, 8 ft (2.4 m) each
one prewired 6 ft (1.8 m) line cord
one outdoor air temperature sensor
optional zone control input
optional boiler On/Off output.
Note: Dimensions in inches unless otherwise stated.
TM03 8839 4412
0 2 4 6 8 10 12 Q [US GPM]
0
2
4
6
8
10
12
14
16
[ft]
H
0.0 0.5 1.0 1.5 2.0 2.5 3.0 Q [m³/h]
0
1
2
3
4
5
[m]
H
a. MIN - both models
b. UP15-42BUC5
c. UP15-42BUC7
60 Hz
c
b
a
Flow range: 0 - 13.5 gpm (0 - 3.1 m
3
/h)
Head range: 0-15 ft (0 - 4.6 m)
Motor: 2-pole, single-phase
Max. liquid temperature: 205 °F (96 °C)
Min. liquid temperature: 36 °F (2 °C)
Max. system pressure: 145 psi (10 bar)
Model Volts Amps Watts Hp Capacitor
UP 15-42 BUC5/MR 115 0.74 85 0.114 10 μF / 180 V
UP 15-42 BUC7/MR 115 0.74 85 0.114 10 μF / 180 V
Drinking Water System Components
In Accordance with NSF/A NSI 372
UP 15-42 BUC5/MR UP 15-42 BUC7/MR
TM03 8755 2407
TM03 8756 2407
Model
Product
number
115 V
Dimensions [inches (mm)]
Connection type
and size
Shipping weight
[lbs (kg)]
ABCDE
UP 15-42 BUC5/MR 59896805 5.31 (135) 5.00 (127) 4.13 (105) 3.50 (89) 3.33 (84) 1/2" sweat 14.3 (6.5)