UP/UPS Pumps Product Guide
Table Of Contents
- 1. Cross-reference charts
- 2. Performance ranges
- 3. Product range
- 4. Identification
- 5. Applications
- 6. Technical data
- UP 10-16 Comfort PM, PM Auto
- UP 10-16 Comfort PM, PM Auto, PM Temperature
- UP 15-10 B5/B7
- UP 15-10 BUC5/BUC7
- UP 15-10 F/FR
- UP Comfort System
- UP 15-18 B5/B7
- UP 15-18 BUC5/BUC7
- UP 15-29 SU/SF
- UP 15-35 SUC
- UPS 15-35 SUC/SFC
- UP 15-42 B5/B7
- UP 15-42 BUC5/BUC7
- UP 15 MixiMizer™
- UP 15-42 F/FR
- UPS 15-42 F
- UP 15 MixiMizer™
- UP variable speed
- UP 15-55 SUC
- UPS 15-55 SFC/SUC/TLC
- ALPHA2
- ALPHA2
- ALPHA1
- ALPHA1
- UPS 15-58 FC/FRC
- UP 15-100 F
- UP 26-64 F
- UP 26 variable speed
- UP 26-96 F/SF
- UP 26 variable speed
- UP 26-99 F/SF
- UPS 26-99 FC/SFC
- UP 26-116 F/SF
- UP 26-120 U
- UPS 26-150 F/SF
- UP 43-44 F/BF
- UPS 43-44 FC/BFC
- UP 43-70 F
- UP 43-75 F/BF
- UPS 43-100 F/SF
- UP 43-110 F
- UPS 50-44 F
- UPS 50-60 F/SF
- UP 50-75 F
- 7. Accessories
- 8. Grundfos Product Center
Technical data
UP Series
6
67
ALPHA1
Approximate power usage
Approvals
TM06 8983 1517
Speed setting
Min.
[W]
Max.
[W]
Constant pressure I 8 45
Constant pressure II 14 45
Constant pressure III 22 45
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Q [US GPM]
0
2
4
6
8
10
12
14
16
18
20
[ft]
H
0
1
2
3
4
5
6
[m]
H
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0
Q [m³/h]
Constant
Pressure III
Constant
Pressure II
Constant
Pressure I
17 18
Flow range: 0 - 17 gpm (0 - 3.9 m
3
/h)
Head range: 0 - 19 ft (0 - 5.8 m)
Motor:
4-pole, synchronous
permanent magnet motor
Max. liquid temperature: 230 °F (110 °C)
Min. liquid temperature: 36 °F (2 °C)
Max. system pressure: 150 psi (10 bar)
Closed (F, FR) and open systems (SF)
Model Volts Amps Watts Hp Capacitor
ALPHA1 15-55 115 0.15 - 0.65 8-45 0.007 - 0.061 -
Canadian
EMC Standard:
ICES-003
This Class B digital
apparatus complies with
Canadian
ICES-003
3191277
Conforms to
ANSI/UL Std. 778
Certified to
CAN/CSA Std. C22.2 No. 108
Drinking Water System Component
NSF/ANSI 61
NSF/ANSI 372