UP/UPS Pumps Product Guide

Table Of Contents
Technical data
UP Series
6
76
UPS 26-99 FC/SFC
Approvals
Note: The check valve can be removed.
Dimensions in inches unless otherwise stated.
TM03 8195 4516
     4>86*30@





>IW@
+
4>PñK@
>P@
+
836)&6)&
+]
Flow range: 0-33 gpm (0 - 7.5 m
3
/h)
Head range: 0-29 ft (0 - 8.8 m)
Motor: 2-pole, single-phase
Max. liquid temperature: 230 °F (110 °C)
Min. liquid temperature: 36 °F (2 °C)
Max. system pressure: 145 psi (10 bar)
Model Speed Volts Amps Watts Hp Capacitor
UPS 26-99 FC
III
115
1.8 197 0.265 20 μF / 180 V
II 1.5 179 0.240 20 μF / 180 V
I 1.3 150 0.202 20 μF / 180 V
UPS 26-99 FC/
SFC
III
230
0.9 196 0.263 5 μF / 400 V
II 0.8 179 0.240 5 μF / 400 V
I 0.7 150 0.202 5 μF / 400 V
Without check valve
With check valve
UP 26-99 F/SFC UP 26-99 SFC
Drinking Water System Components
In Accordance with NSF/A NSI 372
UPS 26-99 FC UPS 26-99 SFC
TM03 8757 2407
TM03 8757 2407
Model
Product number Dimensions [inches (mm)]
Connection type
and size
Shipping
weight
[lbs (kg)]
115 V 230 V A B C D E F
UPS 26-99 FC 52722512 52722513 6.50 (165) 6.00 (152) 4.88 (124) 3.50 (89) 3.44 (87) 3.16 (80)
GF 15/26 flange
(2) 1/2" dia. bolt holes
10.3 (4.7)
UPS 26-99 SFC 98961763 98961765 6.50 (165) 6.00 (152) 4.88 (124) 3.50 (89) 3.44 (87) 3.16 (80)
GF 15/26 flange
(2) 1/2" dia. bolt holes
10.3 (4.7)