UP/UPS Pumps Product Guide
Table Of Contents
- 1. Cross-reference charts
- 2. Performance ranges
- 3. Product range
- 4. Identification
- 5. Applications
- 6. Technical data
- UP 10-16 Comfort PM, PM Auto
- UP 10-16 Comfort PM, PM Auto, PM Temperature
- UP 15-10 B5/B7
- UP 15-10 BUC5/BUC7
- UP 15-10 F/FR
- UP Comfort System
- UP 15-18 B5/B7
- UP 15-18 BUC5/BUC7
- UP 15-29 SU/SF
- UP 15-35 SUC
- UPS 15-35 SUC/SFC
- UP 15-42 B5/B7
- UP 15-42 BUC5/BUC7
- UP 15 MixiMizer™
- UP 15-42 F/FR
- UPS 15-42 F
- UP 15 MixiMizer™
- UP variable speed
- UP 15-55 SUC
- UPS 15-55 SFC/SUC/TLC
- ALPHA2
- ALPHA2
- ALPHA1
- ALPHA1
- UPS 15-58 FC/FRC
- UP 15-100 F
- UP 26-64 F
- UP 26 variable speed
- UP 26-96 F/SF
- UP 26 variable speed
- UP 26-99 F/SF
- UPS 26-99 FC/SFC
- UP 26-116 F/SF
- UP 26-120 U
- UPS 26-150 F/SF
- UP 43-44 F/BF
- UPS 43-44 FC/BFC
- UP 43-70 F
- UP 43-75 F/BF
- UPS 43-100 F/SF
- UP 43-110 F
- UPS 50-44 F
- UPS 50-60 F/SF
- UP 50-75 F
- 7. Accessories
- 8. Grundfos Product Center
Technical data
UP Series
6
86
UPS 50-44 F
Approvals
Note: Dimensions in inches unless otherwise stated.
TM03 8837 4412
UPS 50-44 F
TM04 54713209
0 5 10 15 20 25 30 35 40 45 50 55 Q [US GPM]
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
[ft]
H
0 2 4 6 8 10 12 14Q [m³/h]
0.0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
4.0
[m]
H
UPS50-44F
60 Hz
1
2
3
Flow range: 0-65 gpm (0 - 14.8 m
3
/h)
Head range: 0 - 14.4 ft (0 - 4.4 m)
Motor: 2-pole, single-phase
Max. liquid temperature: 230 °F (110 °C)
Min. liquid temperature: 32 °F (0 °C)
Max. system pressure: 145 psi (10 bar)
Model Speed Volts Amps Watts Hp Capacitor
UPS 50-44 F
III
115
1.8 194 0.261
20 μFII 1.6 181 0.243
I 1.3 147 0.198
III
230
0.90 195 0.262
5 μFII 0.81 182 0.244
I 0.74 147 0.198
Model
Product number Dimensions [inches (mm)]
Connection type
and size
Shipping
weight
[lbs (kg)]
115 V 230 V A B C D E F
UPS 50-44 F 52722557 52722558 8.50 (216) 7.50 (191) 5.06 (129) 4.88 (124) 3.50 (89) 4.19 (106)
GF 50 flange
(4) 1/2" dia. bolt holes
15.5 (7.0)