GRUNDFOS DATA BOOKLET UP Series Circulators 60 Hz
UP Series Contents 1. Cross reference charts 3 6. Quick cross reference for competitive 3-speed pumps 2. 3. 4. 5.
1 UP Series Cross reference charts 1. Cross reference charts Quick cross reference for competitive 3-speed pumps Competitor cross-reference Model Speed High ALPHA 15-55 F/SF UPS 15-58 FC/FRC Med.
1 UP Series Cross reference charts Reference for replacing ALPHA models Competitor cross-reference Model ALPHA 15-55 F/SF Speed TACO* Bell & Gossett* Armstrong* High 005F, 007F, 008F, 0010F-IFC,00R-MSF1-IFC NRF-22, LR-20WR Astro 30, Astro 50-3 Med.
1 UP Series Cross reference charts Reference for replacing TACO models Open systems: Stainless steel and lead-free bronze body pumps Competitor cross-reference for TACO Open systems: Stainless steel and lead-free bronze body pumps TACO model type Port to port length [in] Port to port length [in] Flange size/ conn.
1 UP Series Cross reference charts Competitor cross-reference for TACO Open systems: Stainless steel and lead-free bronze body pumps TACO model type Port to port length [in] Flange size/ conn. type 006-BC7-1PNP 4-13/32 1/2” Sweat 006-BC7-2PNP 4-3/8 3/4” Sweat 006-BC7-3PNP 4-13/32 3/4” Sweat Port to port length [in] Flange size/ conn.
1 Cross reference charts UP Series Competitor cross-reference for TACO Open systems: Stainless steel and lead-free bronze body pumps TACO model type Port to port length [in] Port to port length [in] Flange size/ conn.
1 UP Series Cross reference charts Competitor cross-reference for TACO Open systems: Stainless steel and lead-free bronze body pumps TACO model type Port to port length [in] Port to port length [in] Flange size/ conn.
1 Cross reference charts UP Series Competitor cross-reference for TACO Closed systems: Cast iron body pumps TACO model type Port to port length [in] Port to port length [in] Flange size/ conn. type 1x115V 1x208V 1x230V 3x208V 3x230V UP 15-100 F 6-1/2” 2-Bolt Flange 59896300 - - - - - Magna 32-60 F 6-1/2” 2-Bolt Flange - 98071395 98071395 98071395 98071395 - Flange size/ conn.
1 UP Series Cross reference charts Competitor cross-reference for TACO Closed systems: Cast iron body pumps TACO model type Port to port length [in] Flange size/ conn.
1 UP Series Cross reference charts Reference for replacing Bell & Gossett models Open systems: Stainless steel and lead-free bronze body pumps Competitor cross-reference for Bell & Gossett Open systems: Stainless steel and lead-free bronze body pumps Port to port length [in] Flange size/ conn.
1 UP Series Cross reference charts Closed systems: Cast iron body pumps Competitor cross-reference for Bell & Gossett Closed systems: Cast iron body pumps Bell & Gossett model type NRF-9F/LW NRF-22 Port to port length [in] 6-3/8” 6-3/8” 2-Bolt Flange-R 2-Bolt Flange-R NRF-25 6-3/8” 2-Bolt Flange NRF-33 6-3/8” 2-Bolt Flange NRF-36 NRF-45 6-3/8” 8-1/2” Port to port length [in] Flange size/ conn.
1 UP Series Cross reference charts Reference for replacing Laing models Competitor cross-reference for Laing Open systems: Stainless steel and lead-free bronze body pumps Laing model type Port to port length [in] Flange size/ conn. type Port to port length [in] Flange size/ conn.
1 UP Series Cross reference charts Reference for replacing Armstrong models Open systems: Stainless steel and lead-free bronze body pumps Competitor cross-reference for Armstrong Open systems: Stainless steel and lead-free bronze body pumps Port to port length [in] Flange size/ conn.
1 UP Series Cross reference charts Closed systems: Cast iron body pumps Competitor cross-reference for Armstrong Closed systems: Cast iron body pumps Armstrong model type Port to port length [in] Port to port length [in] Flange size/ conn.
1 UP Series Cross reference charts Reference for replacing Wilo models Open systems: Stainless steel and lead-free bronze body pumps Competitor cross-reference for Wilo Open systems: Stainless steel and lead-free bronze body pumps Port to port length [in] Flange size/ conn. type Star Z-15 BN5 3-1/8" 1/2" Union NPT Star Z-15 BS5 3-1/8" Star Z-15 BS7 3-1/8" Wilo model type Port to port length [in] Flange size/ conn.
1 UP Series Cross reference charts Discontinued products The table shows which new products replace discontinued products.
2 UP Series Performance ranges 2.
2 UP Series Performance ranges 3-speed stainless steel H UPS [ft] 18 60 Hz 16 14 UPS 15-55 12 10 8 6 UPS 15-35 2 0 0 2 4 6 8 10 12 14 16 18 20 22 24 26 Q [US GPM] TM04 5462 3109 4 Comfort pump H [m] H [ft] a. UP10-16B5 b. UP10-16BN5 60 Hz 5.0 1.4 1.2 b 4.5 4.0 a 3.5 1.0 3.0 0.8 0.6 2.5 2.0 1.5 0.4 1.0 0.0 0.5 0.0 0.0 0.0 0.4 0.1 0.8 0.2 1.2 0.3 1.6 0.4 2.0 2.4 0.5 2.8 0.6 3.2 Q [US GPM] 0.7 Q [m³/h] TM03 8851 2807 0.2 Note: a. UP 10-16 B5 b.
2 UP Series Performance ranges Closed systems H [ft] 36 1. 2. 3. 4. 5. 6. 7. 8. 9. 1 32 2 28 4 24 UP 26-116 F UP 26-99 F UP 43-75 F UP 26-96 F UP 26-64 F UP 15-42 F UP 15-10 F/FR UP 15-100 F UP 26-120 U 5 20 3 8 16 6 12 8 0 0 4 8 12 16 20 24 28 32 36 40 44 Q [US GPM] TM03 9128 3407 9 7 4 Open systems H [ft] 32 10. UP 26-99 BF 11. UP 43-75 BF 12. UP 26-96 BF 13. UPS 15-55 SU/SF 14. UPS 15-35 SU/SF 15. UP 15-29 SU/SF 16. UPS 26-99 BFC 17.
2 UP Series H [ft] 1. UP 15-42 B5 2. UP 15-18 B5 3. UP 15-10 B5 4. UP 15-42 BUC5 5. UP 15-18 BUC5 6. UP 15-10 BUC5 4 15 Performance ranges Open systems 1/2" 14 13 12 11 10 9 8 1 7 6 5 5 4 2 3 3 1 0 0 1 2 3 4 5 6 7 8 9 10 11 12 Q [US GPM] TM03 9131 3507 6 2 Open systems 3/4" H [ft] 7. UP 15-42 B7 8. UP 15-18 B7 9. UP 15-10 B7 10. UP 15-42 BUC7 11. UP 15-18 BUC7 12.
3 UP Series Product range 3.
3 UP Series Product number Open systems UP 10-16 B5/LC UP 10-16 B5/TLC UP 10-16 B5/ATLC UP 10-16 BN5/LC UP 10-16 BN5/TLC UP 10-16 BN5/ATLC UP 10-16 BU/ATLC UP 15-10 B5 UP 15-10 B5/LC UP 15-10 B5/TLC UP 15-10 B7 UP 15-10 B7/LC UP 15-10 B7/TLC UP 15-10 BUC5 UP 15-10 BUC5/LC UP 15-10 BUC5/TLC UP 15-10 BUC7 UP 15-10 BUC7/LC UP 15-10 BUC7/TLC UP 15-18 B5 UP 15-18 B5/LC UP 15-18 B5/TLC UP 15-18 B7 UP 15-18 B7/LC UP 15-18 B7/TLC UP 15-18 BUC5 UP 15-18 BUC7 UP 15-42 B5 UP 15-42 B5/LC UP 15-42 B5/TLC UP 15-42 B7 U
3 UP Series Product range Stainless steel Product number Open systems UP 15-10 SU7P/TLC* UP 15-29 SF UP 15-29 SU UP 15-29 SU/LC UP 15-29 SUC/TLC UP 15-35 SUC UPS 15-35 SFC UPS 15-35 SUC UP 15-35 SUC/TLC UP 15-55 SUC UPS 15-55 SFC UPS 15-55 SUC UPS 15-55 SUC/TLC UPS 26-150 SF UPS 43-100 SF UPS 50-60 SF Head Flanged Union NPT Sweat 230 V [gpm] [m3h] [ft] [m] 595916 59896771 59896775 59896776 59896777 59896772 59896778 59896780 59896773 59896781 59896783 95906632 95906638 97523136 59896784 59896785 5
4 UP Series Identification 4.
4 UP Series Identification Nameplate NONSUBMERSIBLE CIRCULATION PUMP Type UP 15 - 42F P/N: 59896155 115 V 1PH PC: 0452 P1 60Hz US 10uF Class F IMPEDANCE PROTECTED I1/1 (A) P1 (W) .74 85 - FOR INDOOR USE ONLY MAX FLUID TEMP. 230F 99K4 C UL US LISTED NONSUBMERSIBLE CIRCULATION PUMP Type UP 15 - 42F P/N: 59896155 115 V 1PH PC: 0452 P1 60Hz US 10uF Class F IMPEDANCE PROTECTED I1/1 (A) P1 (W) .74 85 - FOR INDOOR USE ONLY MAX FLUID TEMP.
5 UP Series The Grundfos circulator pumps, Series UP(S), are specifically designed for heating systems. The pumps are also suitable for circulation of hot domestic water and for circulation of liquid in cooling and airconditioning systems.
5 UP Series Installation Description (UP closed systems) The pump must always be installed with horizontal motor shaft.
5 UP Series Pumped liquids Depending on type, Grundfos circulator pumps are designed for the following liquids: • Potable water Applications The ambient temperature for standard pumps with a permissible liquid temperature from 36 °F (2 °C) to 230 °F (110 °C) should always be lower than the liquid temperature, as otherwise condensation may form in the stator housing. • Non-potable water • Water-glycol mixtures Maximum system pressure • Chilled water 145 psi (10 bar).
5 UP Series Applications ALPHA Control display The Grundfos Alpha is the next generation of energy efficient wet-rotor circulators. By incorporating a permanent magnet motor design, power consumption is now reduced by a minimum of 50 %. By using the AutoADAPT™ feature, Grundfos ALPHA will automatically analyze the system demands and adjust head and or flow requirements to meet changing heating demands.
5 UP Series The Grundfos MixiMizer, a fully integrated injection pump and indoor/outdoor controller, is the only pump and controller system of its kind. Equipped with a weather responsive control, also known as indoor/outdoor control or reset control, the MixiMizer automatically calculates and controls mixed water temperatures according to outdoor temperatures in primary/secondary piping systems.
5 UP Series The Grundfos variable-speed pump is another product with fully integrated control. The variable-speed controller requires a 0-10/2-10 DC or 0-20/4-20 mA control signal, which is user-selectable. If desired, the manual-% dial allows the speed of the pump to be manually adjusted and set by the user. The speed of the pump may be manually adjusted anywhere from min. to 100 %, but once set, remains fixed at that speed. In addition, the pump speed may be set as 0-100 % or 15-100 % by user.
5 Comfort System The Comfort System uses a patented Comfort Valve® and pump to provide instant availability of hot water at the point of use. Operation The Comfort Valve® is installed at the fixture furthest away from the hot-water tank. With a built-in timer, the pump allows hot water to circulate along the loop through the valve using the cold-water side as a return line.
5 UP Series Applications UP 10 Comfort pump The water-conduction part of the pump is hermetically separated from the stator with a stainless steel spherical separator. The motor can be separated from the pump housing, enabling easy maintenance and replacement. Applications • Domestic hot-water recirculation systems in singleand two-family houses • Small heating systems.
6 UP Series UP 10 Comfort Pump UP 10-16 B5/BN5/BU H [m] H [ft] a. UP10-16B5 b. UP10-16BN5 UP10-16BU 60 Hz 5.0 1.4 1.2 1.0 b 4.5 4.0 0.6 0.4 0-3.5 gpm (0-0.8 m3h) Head range: 0-5.4 ft (0-1.6 m) Motors: Single-phase Max. liquid temperature: 203 °F (95 °C) Min. liquid temperature: 36 °F (2 °C) Max. system pressure: 145 psi (10 bar) a 3.5 Model 3.0 0.8 Flow range: Technical data 6. Technical data Volts Amps Watts Hp Capacitor 115 0.23 25 - - UP 10-16 B5/BN5/BU 2.
6 UP Series Technical data UP 15-10 B5/B7 H [m] H [ft] a. UP15-10B5 b. UP15-10B7 60 Hz 7 2.0 b 6 a 1.6 Head range: 0-6.2 ft (0-1.9 m) Motors: 2-pole, single-phase Max. liquid temperature: 220 °F (104 °C) Min. liquid temperature: 36 °F (2 °C) Max. system pressure: 145 psi (10 bar) Note: If the UP pump is equipped with a timer, the maximum liquid temperature is 150 °F (66 °C). 5 1.2 0-8.2 gpm (0-1.9 m3h) Flow range: 4 Model Volts Amps Watts Hp Capacitor 115 0.
6 UP 15-10 BUC5/BUC7 H [m] 2.0 6.5 1.8 6.0 a 5.5 a. UP15-10BUC5 b. UP15-10BUC7 60 Hz b 1.6 5.0 1.4 4.5 1.2 4.0 0.6 0.4 Head range: 0-6.6 ft (0-2 m) Motors: 2-pole, single-phase Max. liquid temperature: 230 °F (110 °C) Min. liquid temperature: 36 °F (2 °C) Max. system pressure: 145 psi (10 bar) Note: If the UP pump is equipped with a timer, the maximum liquid temperature is 150 °F (66 °C). 3.5 Model 3.0 UP 15-10 BUC5/BUC7 1.0 0.8 0-6.6 gpm (0-1.
6 UP Series Technical data UP 15-10 F/FR H [m] 2.0 0-8.0 gpm (0-1.8 m3h) Flow range: H [ft] UP15-10F/FR 60 Hz 6 1.6 5 Head range: 0-5.5 ft (0-1.7 m) Motors: 2-pole, single-phase Max. liquid temperature: 230 °F (110 °C) Min. liquid temperature: 36 °F (2 °C) Max. system pressure: 145 psi (10 bar) Closed system 1.2 4 Model UP 15-10 F/FR 3 Volts Amps Watts Hp Capacitor 115 0.23 25 1/25 2μF/400 V 0.8 Approvals 2 0.4 0.0 0 0 1 0.0 2 3 4 0.5 5 6 1.0 7 Q [US GPM] 1.
6 UP Comfort System UP 15-10 SU7P/TLC H [m] H [ft] UP15-10SU7P/TLC 60 Hz 5.0 1.4 1.2 4.5 Flow range: 0-6.3 gpm (0-1.4 m3h Head range: 0-5.1 ft (0-1.6 m) Motors: 2-pole, single-phase Max. liquid temperature: 150 °F (66 °C) Min. liquid temperature: 36 °F (2 °C) Max. system pressure: 145 psi (10 bar) Technical data UP Series Open system 4.0 Model 3.5 1.0 UP 15-10 SU7P/TLC Volts Amps Watts Hp Capacitor 115 0.23 25 1/25 2μF/400 V 3.0 0.8 0.6 2.5 Approvals 2.0 1.5 0.4 0.
6 UP Series Technical data UP 15-18 B5/B7 H [m] H [ft] a. UP15-18B5 b. UP15-18B7 60 Hz 14 4.0 13 12 3.5 11 3.0 2.0 0-14.7 gpm (0-3.3 m3h) Head range: 0-13.9 ft (0-4.2 m) Motors: 2-pole, single-phase Max. liquid temperature: 230 °F (110 °C) Min. liquid temperature: 36 °F (2 °C) Max. system pressure: 145 psi (10 bar) 10 Note: If the UP pump is equipped with a timer, the maximum liquid temperature is 150 °F (66 °C). 9 2.5 Flow range: 8 7 Model 6 1.
6 UP 15-18 BUC5/BUC7 H [m] 5 H [ft] a. UP15-18BUC5 b. UP15-18BUC7 60 Hz 16 b Flow range: 0-14.7 gpm (0-3.3 m3h) Head range: 0-14.5 ft (4.4 m) Motors: 2-pole, single-phase Max. liquid temperature: 230 °F (110 °C) Min. liquid temperature: 36 °F (2 °C) Max. system pressure: 145 psi (10 bar) Technical data UP Series 14 a 4 12 3 10 Model 8 2 6 Volts Amps Watts Hp Capacitor UP 15-18 BUC5 115 0.74 86 1/25 10μF/180 V UP 15-18 BUC7 115 0.74 86 1/25 10μF/180 V 4 1 0 0 0 0.
6 UP Series Technical data UP 15-29 SU/SF H [m] 3.0 2.5 Flow range: 0-20.5 gpm (0-4.7 m3h) Head range: 0-9.7 ft (0-2.2 m) Motors: 2-pole, single-phase 9 Max. liquid 230 °F (110 °C) and 150 °F 8 Min. liquid temperature: 36 °F (2 °C) 7 Max. system pressure: 6 Open system H [ft] UP15-29 60 Hz 10 2.0 1.5 145 psi (10 bar) Note: If the UP pump is equipped with a timer, the maximum liquid temperature is 150 °F (66 °C). 5 4 Model Volts Amps Watts Hp 0.75 87 0.12 0.75 87 0.
6 UP 15-35 SUC H [m] 4 H [ft] UP15-35SUC 60 Hz 12 3 10 Flow range: 0-17.5 gpm (0-4.0 m3h) Head range: 0-11.5 ft (3.5 m) Motors: 2-pole, single-phase Max. liquid temperature: 230 °F (110 °C) Min. liquid temperature: 36 °F (2 °C) Max. system pressure: 145 psi (10 bar) 8 Open system 6 Model Technical data UP Series 2 Volts Amps Watts Hp Capacitor 230 0.50 114 0.
6 UP Series Technical data UPS 15-35 SUC/SFC H [m] H [ft] 12 3 3.5 3.0 UPS15-35 60 Hz 0-21.5 gpm (0-4.9 m3h) Head range: 0-12 ft (0-3.7 m) Motors: 2-pole, single-phase 11 Max. liquid temperature: 165 °F (74 °C) 10 Min. liquid temperature: 36 °F (2 °C) Max. system pressure: 145 psi (10 bar) 9 2.5 Flow range: 8 Note: If the UP pump is equipped with a timer, the maximum liquid temperature is 150 °F (66 °C). 2 7 2.0 6 3 0.5 UPS 15-35 SUC/ SFC 1 4 1.
6 UP 15-42 B5/B7 H [m] 5 a. UP15-42B5 b. UP15-42B7 60 Hz 16 b 14 a 4 0-17 gpm (0-3.9 m3h) Flow range: H [ft] Technical data UP Series Head range: 0-15 ft (0-4.6 m) Motors: 2-pole, single-phase Max. liquid temperature: 230 °F (110 °C) Min. liquid temperature: 36 °F (2 °C) Max. system pressure: 145 psi (10 bar) 12 Note: If the UP pump is equipped with a timer, the maximum liquid temperature is 150 °F (66 °C). 10 Model 8 2 Amps Watts Hp Capacitor 115 0.
6 UP Series Technical data UP 15-42 BUC5/BUC7 H [m] 5 H [ft] a. UP15-42BUC5 b. UP15-42BUC7 60 Hz 16 14 4 12 3 Flow range: 0-17 gpm (0-3.9 m3h) Head range: 0-15 ft (0-4.6 m) Motors: 2-pole, single-phase Max. liquid temperature: 205 °F (96 °C) Min. liquid temperature: 36 °F (2 °C) Max. system pressure: 145 psi (10 bar) 10 Model 8 6 2 Volts Amps Watts Hp Capacitor UP 15-42 BUC5 115 0.74 85 1/25 10μF/180 V UP 15-42 BUC7 115 0.
6 UP 15 MixiMizer UP 15-42 BUC5/BUC7/MR H [m] 5 H [ft] a. MIN - both models b. UP15-42BUC5 c. UP15-42BUC7 60 Hz 16 c 14 Flow range: 0-13.5 gpm (0-3.1 m3h) Head range: 0-15 ft (0-4.6 m) Motors: 2-pole, single-phase Max. liquid temperature: 205 °F (96 °C) Min. liquid temperature: 36 °F (2 °C) Max. system pressure: 145 psi (10 bar) Technical data UP Series 4 b 12 Model 3 10 8 Volts Amps Watts Hp Capacitor UP 15-42 BUC5/MR 115 0.74 85 1/25 10μF/180 V UP 15-42 BUC7/MR 115 0.
6 UP Series Technical data UP 15-42 F/FR H [m] 5 H [ft] UP15-42F/FR 60 Hz 16 14 4 12 3 Flow range: 0-17 gpm (0-3.9 m3h) Head range: 0-15 ft (0-4.6 m) Motors: 2-pole, single-phase Max. liquid temperature: 230 °F (110 °C) Min. liquid temperature: 36 °F (2 °C) Max. system pressure: 145 psi (10 bar) Closed system 10 8 Model 2 6 Volts Amps Watts Hp Capacitor 115 0.74 85 1/25 10μF/180 V 230 0.43 95 1/25 2μF/400 V UP 15-42 F/FR 4 2 0 0 0 0.0 2 4 0.5 1.0 6 8 1.
6 UPS 15-42 F H [m] 5 H [ft] UPS15-42F 60 Hz 16 3 Flow range: 0-17.5 gpm (0-4.0 m3h) Head range: 0-15.5 ft (14.7 m) Motors: 2-pole, single-phase Max. liquid temperature: 230 °F (110 °C) Min. liquid temperature: 36 °F (2 °C) Max. system pressure: 145 psi (10 bar) Technical data UP Series 14 4 2 12 3 10 Model Speed Volts Amps Watts 8 3 2 1 6 UPS 15-42 F 2 1 230 0.41 92 0.19 40 0.14 30 Hp Capacitor 1/25 2μF/400 V 4 2 0 0 0 0.0 2 4 0.5 6 1.0 8 1.5 10 2.
6 UP Series Technical data UP 15 MixiMizer UP 15-42 FC/MR H [m] 5 H [ft] a. MIN - UP15-42FC/MR b. MAX - UP15-42FC/MR 60 Hz 16 b 14 Flow range: 0-16 gpm (0-3.6 m3h) Head range: 0-15 ft (0-4.6 m) Motors: 2-pole, single-phase Max. liquid temperature: 205 °F (96 °C) Min. liquid temperature: 36 °F (2 °C) Max. system pressure: 145 psi (10 bar) 4 Model 12 3 UP 15-42 FC/MR 10 8 Volts Amps Watts Hp Capacitor 115 0.74 85 1/25 10μF/180 V Approvals 2 6 4 2 a 0 0 0 0.0 2 0.
6 UP Variable Speed Flow range: 0-16 gpm (0-3.6 m3h) Head range: 0-15.5 ft (4.7 m) Motors: 2-pole, single-phase Max. liquid temperature: 205 °F (96 °C) Min. liquid temperature: 36 °F (2 °C) 14 Max. system pressure: 145 psi (10 bar) 12 Model 10 UP 15-42 F/FV UP 15-42 F/VS H [m] 5 H [ft] 16 a. MIN - UP15-42F/FV b. MAX - UP15-42F/FV 60 Hz b Technical data UP Series 4 3 Hp Capacitor 115 0.
6 UP Series Technical data UP 15-55 SUC H [m] H [ft] UP15-55SUC 60 Hz 18 5 16 Flow range: 0-21.5 gpm (0-4.9 m3h) Head range: 0-17 ft (0-5.2 m) Motors: 2-pole, single-phase Max. liquid temperature: 230 °F (110 °C) Min. liquid temperature: 36 °F (2 °C) Max. system pressure: 145 psi (10 bar) 14 4 12 3 Closed system 10 Model Volts Amps Watts Hp Capacitor 230 0.42 97 0.13 2μF/400 V 8 2 UP 15-55 SUC 6 4 Approvals 1 0 0 0 2 4 6 0.0 0.5 1.0 8 1.5 10 2.0 12 2.5 14 3.
6 UPS 15-55 SFC/SUC/TLC H [m] H [ft] UPS15-55SFC/SUC 60 Hz 18 3 5 16 2 14 12 Head range: 0-18 ft (0-5.5 m) Motors: 2-pole, single-phase Max. liquid temperature: 230 °F (110 °C) Min. liquid temperature: 36 °F (2 °C) Max. system pressure: 145 psi (10 bar) Model 10 Speed Volts Amps Watts 1 3 8 2 0-25 gpm (0-5.7 m3h) Note: If the UP pump is equipped with a timer, the maximum liquid temperature is 150 °F (66 °C). 4 3 Flow range: UPS 15-55 SFC 2 6 115 Hp 0.75 87 0.12 0.
6 UP Series Technical data UP 15 ALPHA TM04 6025 0611 Performance* and operation mode selection Pos. Description Pos. Description • Push-button for selection of pump setting • Every time the push-button is pressed, the circulator setting is changed Constant pressure I • The duty point of the pump will move left and right along the lowest constant-pressure curve depending on water demand in the system. The pump head (pressure) is kept constant, irrespective of the water demand.
6 UP 15 ALPHA Flow range: 0-21.5 gpm (4.9 m3h) Head range: 0-17 ft (5.2 m) Motors: 2-pole, single-phase Max. liquid temperature: 230 °F (110 °C) Min. liquid temperature: 36 °F (2 °C) Max. system pressure: 150 psi (10 bar) Closed (F, FR) and open systems (SF) ALPHA 15-55 F Linecord F C G A B Technical data UP Series Volts Amps Watts Hp Capacitor 115 0.65 5 to 45 0.06 - E Model ALPHA 15-55 D TM04 6012 4709 Approximate power usage Speed setting Min. Max.
6 UP Series Technical data UPS 15-58 FC/FRC H [m] 6 H [ft] 20 3 18 5 UPS15-58FC/FRC 60 Hz 2 16 14 4 Flow range: 0-17 gpm (0-3.9 m3h) Head range: 0-19.5 ft (0-5.9 m) Motors: 2-pole, single-phase Max. liquid temperature: 230 °F (110 °C) Min. liquid temperature: 36 °F (2 °C) Max. system pressure: 145 psi (10 bar) 1 12 3 Model 10 Speed Volts Amps Watts 3 8 2 UPS 15-58 FC/ FRC 6 2 1 4 115 Hp Capacitor 0.75 87 1/25 0.66 80 1/25 10μF/180 V 0.55 60 1/25 2 0 0 0 0.
6 UP 15-100 F H [m] H [ft] UP15-100F 60 Hz 36 10 32 Flow range: 0-8.4 gpm (0-1.9 m3h) Head range: 0-36 ft (0-11.0 m) Motors: 2-pole, single-phase Max. liquid temperature: 205 °F (96 °C) Min. liquid temperature: 36 °F (2 °C) Max. system pressure: 145 psi (10 bar) Technical data UP Series 28 8 24 6 Closed system 20 Model Volts Amps Watts Hp Capacitor 115 1.1 135 1/25 12μF/170 V 16 UP 15-100 F 4 12 Approvals 8 4 0 0 0 0.0 1 0.2 2 0.4 3 0.6 4 0.8 5 1.0 6 7 1.4 1.
6 UP Series Technical data UP 26-64 F H [m] 8 Flow range: 0-32 gpm (0-7.3 m3h) Head range: 0-24.5 feet (0-5.7 m) Motors: 2-pole, single-phase Max. liquid temperature: 230 °F (110 °C) 22 Min. liquid temperature: 36 °F (2 °C) 20 Max. system pressure: 145 psi (10 bar) H [ft] UP26-64F 60 Hz 26 24 7 6 18 5 Closed system 16 14 Model 4 Volts Amps Watts Hp Capacitor 115 1.7 185 1/12 8μF/180 V 230 0.8 175 1/12 2.
6 UP 26 Variable Speed UP 26-64 F/VS H [m] 8 H [ft] b 24 6 a. MIN - UP26-64F/VS b. MAX - UP26-64F/VS 60 Hz Flow range: 0-34 gpm (0-7.7 m3h) Head range: 0-24.5 ft (0-7.5 m) Motors: 2-pole, single-phase Max. liquid temperature: 195 °F (91 °C) Min. liquid temperature: 36 °F (2 °C) Max. system pressure: 145 psi (10 bar) Technical data UP Series 20 Model UP 26-64 F/VS 16 Volts Amps Watts Hp Capacitor 115 1.
6 UP Series Technical data UP 26-96 F/BF H [m] 9 \ Flow range: 0-28 gpm (0-6.4 m3h) Head range: 0-30 ft (0-9.1 m) Motors: 2-pole, single-phase Max. liquid temperature: 230 °F (110 °C) Min. liquid temperature: 36 °F (2 °C) 22 Max. system pressure: 145 psi (10 bar) 20 Closed system (F) and open system (BF) H [ft] 30 UP26-96F/BF 60 Hz 28 8 26 24 7 6 18 5 4 16 Model 12 3 Volts Amps Watts Hp Capacitor 115 1.7 205 1/12 10μF/180 V 230 0.8 205 1/12 2.
6 UP 26 Variable Speed UP 26-96 F/VS H [m] 10 H [ft] a. MIN - UP26-96F/VS b. MAX - UP26-96F/VS 60 Hz 32 b Flow range: 0-28 gpm (0-6.4 m3h) Head range: 0-30 ft (0-9.1 m) Motors: 2-pole, single-phase Max. liquid temperature: 195 °F (91 °C) Min. liquid temperature: 36 °F (2 °C) Max. system pressure: 145 psi (10 bar) Technical data UP Series 28 8 Model 24 Volts Amps Watts Hp Capacitor 115 1.
6 UP Series Technical data UP 26-99 F/BF H [m] 10 Flow range: Head range: Motors: Max. liquid temperature: Min. liquid temperature: Max. system pressure: Closed system (F) and open H [ft] UP26-99F/BF 60 Hz 32 28 8 0-34 gpm (7.7 m3h) 0-32 feet (0-9.8 m) 2-pole, single-phase 230 °F (110 °C) 36 °F (2 °C) 145 psi (10 bar) system (BF) 24 Model 6 20 Volts Amps Watts Hp Capacitor 115 2.15 245 1/6 10μF/180 V 230 1.07 245 1/6 2.
6 UPS 26-99 FC/BFC H [m] H [ft] UPS26-99FC/BFC 60 Hz 3 28 2 8 24 1 6 Flow range: 0-33 gpm (0-7.5 m3h) Head range: 0-29 ft (0-8.8 m) Motors: 2-pole, single-phase Max. liquid temperature: 230 °F (110 °C) Min. liquid temperature: 36 °F (2 °C) Max. system pressure: 145 psi (10 bar) Technical data UP Series 20 Model Speed Volts Amps Watts Hp Capacitor 16 3 1.8 197 1/6 20μF/180 V 1.5 179 1/6 20μF/180 V 1 1.3 150 1/6 20μF/180 V 3 0.9 196 1/6 5μF/400 V 0.
6 UP Series Technical data UP 26-116 F/BF H [m] 12 10 Flow range: 0-37 gpm (0-8.4 m3h) Head range: 0-37 ft (0-11.3 m) Motors: 2-pole, single-phase 36 Max. liquid temperature: 150 °F (65 °C) 32 Min. liquid temperature: 32 °F (0 °C) 28 Max. system pressure: 145 psi (10 bar) 24 Closed system (F) and open system (BF) H [ft] UP26-116F/BF 60 Hz 40 8 6 20 Model Volts Amps Watts Hp Capacitor 230 1.8 385 1/6 2.
6 UP 26-120 U H [m] 12 10 Flow range: 0-19 gpm (0-4.3 m3h) Head range: 0-38 ft (0-11.6 m) Motors: 2-pole, single-phase 36 Max. liquid temperature: 203 °F (95 °C) 32 Min. liquid temperature: 32 °F (0 °C) 28 Max. system pressure: 145 psi (10 bar) H [ft] UP26-120U 60 Hz 40 8 Closed system 24 6 Technical data UP Series 20 Model Volts Amps Watts Hp Capacitor 115 2.15 215 1/6 10μF/180 V 230 1.07 220 1/6 2.5μF/380 V 16 4 12 UP 26-120 U 8 4 0 0 0 0.0 2 4 6 0.5 1.
6 UP Series Technical data UPS 26-150 F/SF H [m] 14 12 H [ft] 45 UPS26-150F/SF 60 Hz 3 2 40 Flow range: 0-53 gpm (0-12 m3h) Head range: 0-46 ft (0-14 m) Motors: 2-pole, single-phase Max. liquid temperature: 230 °F (110 °C) Min. liquid temperature: 36 °F (2 °C) Max. system pressure: 145 psi (10 bar) 35 1 10 30 8 6 Model 25 Speed Volts Amps Watts Hp 3.5 370 1/2 3.1 335 1/2 1 2.5 265 1/2 3 1.7 350 1/2 1.5 310 1/2 1 1.2 250 1/2 3 1.7 370 1/2 1.
6 UP 43-44 F/BF H [m] Flow range: 0-68 gpm (0-15.4 m3h) Head range: 0-13.5 ft (0-4.1 m) Motors: 2-pole, single-phase Max. liquid temperature: 230 °F (110 °C) 11 Min. liquid temperature: 32 °F (0 °C) 10 Max. system pressure: 145 psi (10 bar) H [ft] UP43-44F/BF 60 Hz 14 4.0 13 12 3.5 3.0 9 2.5 2.0 Closed system (F) and open system (BF) 8 7 Model 6 1.5 5 2 1 0.0 Amps Watts Hp Capacitor 115 2.15 215 1/6 10μF/180 V 230 1.07 220 1/6 2.
6 UP Series Technical data UPS 43-44 FC/BFC H [m] Flow range: 0-63 gpm (0-14.3 m3h) Head range: 0-14 ft (0-4.3 m) Motors: 2-pole, single-phase 3 Max. liquid temperature: 230 °F (110 °C) 2 Min. liquid temperature: 32 °F (0 °C) Max. system pressure: 145 psi (10 bar) H [ft] UPS43-44FC/BFC 60 Hz 14 4 3 12 2 3 10 1 1 Model Speed Volts Amps Watts Hp Capacitor 8 3 2 UPS 43-44 FC/ BFC 6 1.8 203 1/6 20μF/180 V 1.7 189 1/6 20μF/180 V 1 1.4 157 1/6 20μF/180 V 3 0.
6 UP 43-70 F H [m] 8 7 6 5 4 3 Flow range: 85 gpm (19.3 m3h) Head range: 24.5 ft (7.5 m) Motors: 2-pole, single-phase Max. liquid temperature: 230 °F (110 °C) Min. liquid temperature: 14 °F (-10 °C) 18 Max. system pressure: 145 psi (10 bar) 16 Closed system H [ft] UP43-70F 60 Hz 26 24 22 20 14 Model 12 10 Watts Hp Capacitor 115 3.4 400 1/2 30μF 230 1.
6 UP Series Technical data UP 43-75 F/BF H [m] 8 Flow range: 0-41 gpm (0-9.3 m3h) Head range: 0-25 ft (0-7.6 m) Motors: 2-pole, single-phase Max. liquid temperature: 230 °F (110 °C) 20 Min. liquid temperature: 36 °F (2 °C) 18 Max. system pressure: 145 psi (10 bar) 16 Open system H [ft] UP43-75F/BF 60 Hz 26 24 7 22 6 5 14 4 12 3 Model 10 4 2 0 Watts Hp Capacitor 115 2.15 215 1/6 10μF/180 V 230 1.07 220 1/6 2.
6 UPS 43-100 F/SF H [m] H [ft] UPS43-100F/SF 10 32 60 Hz 3 2 28 1 8 24 Flow range: 0-65 gpm (0-14.8 m3h) Head range: 0-31 ft (9.5 m) Motors: 2-pole, single-phase Max. liquid temperature: 230 °F (110 °C) Min. liquid temperature: 36 °F (2 °C) Max.
6 UP Series Technical data UP 43-110 F H [m] H [ft] UP43-110F 36 10 60 Hz 32 Flow range: 0-98 gpm (0-22.3 m3h) Head range: 0-37 ft (0-11.3 m) Motors: 2-pole, single-phase Max. liquid temperature: 230 °F (110 °C) Min. liquid temperature: 14 °F (–10 °C) Max. system pressure: 145 psi (10 bar) 28 8 24 6 Closed system 20 Model 16 4 Volts Amps Watts Hp Capacitor 115 5.1 590 3/4 60μF 230 2.
6 UPS 50-40 F H [m] H [ft] 3 14 3 4.0 UPS50-44F 60 Hz 2 2 13 12 3.5 11 1 1 3.0 10 Flow range: 0-65 gpm (0-14.8 gpm) Head range: 0-14.4 ft (4.4 m) Motors: 2-pole, single-phase Max. liquid temperature: 230 °F (110 °C) Min. liquid temperature: 32 °F (0 °C) Max. system pressure: 145 psi (10 bar) Technical data UP Series 9 2.5 8 Model 2.0 1.5 Speed Volts Amps Watts Hp Capacitor 7 6 3 5 1.8 194 1/6 2 1.6 181 1/6 1 1.3 147 1/6 3 0.90 195 1/6 0.81 182 1/6 0.
6 UP Series Technical data UPS 50-60 F/SF H [m] H [ft] 22 3 20 6 UPS 50-60 F/SF 60 Hz 2 18 5 16 14 4 Motors: 2-pole, single-phase Max. liquid temperature: 230 °F (110 °C) Min. liquid temperature: 36 °F (10 °C) Max. system pressure: 145 psi (10 bar) Speed Volts Amps Watts Hp 8 3 3.6 395 1/2 6 2 3.4 350 1/2 4 1 2.7 260 1/2 3 1.9 395 1/2 1.7 350 1/2 1 1.4 290 1/2 3 1.8 395 1/2 1.7 350 1/2 1.4 260 1/2 2 0 21 ft (6.
6 UP 50-75 F H [m] 8 H [ft] UP50-75F 60 Hz 26 24 7 22 6 20 Flow range: 0-41 gpm (0-9.3 m3h) Head range: 0-25 ft (0-7.6 m) Motors: 2-pole, single-phase Max. liquid temperature: 230 °F (110 °C) Min. liquid temperature: 32 °F (0 °C) Max. system pressure: 145 psi (10 bar) Technical data UP Series 18 5 Closed system 16 14 4 Model 12 3 10 Volts Amps Watts Hp Capacitor 115 2.15 215 1/6 10μF/180 V 230 1.07 220 1/6 2.
7 UP Series Accessories 7. Accessories UP timer 4.25 in (108 mm) Specifications (previous/current) 2.95 in (75 mm) Type: 24-hour, 3-position On/Timer/Off 15-minute interval • Size: 3.77 x 2.85 x 1.25" • Supply voltage: 120 VAC • Power consumption: 1 VA Switch rating: SPDT • Resistive: 21A/6 A • Tungsten: 1350 W. • Inductive: 1 HP @ 120 VAC; 2 HP @ 240 VAC Wiring connections: 1/4" quick-connects. TM03 4406 1311 2.85 (73) 1.6 in (41 mm) 3.
7 UP Series Accessories AquaStat Specifications • • • • Description: Thermostatic switch. Type: Bi-metallic disc, snap acting. Enclosure: environmentally sealed. Mounting: - Clip-on mount for 1/2 in. (12.7 mm) I.D. copper tube (5/8 in. (15.9 mm) O.D.) - Clip-on mount for 3/4 in. (19.1 mm) I.D. copper tube (7/8 in. (22.2 mm) O.D.). • Contact rating: - 10 A @ 120 VAC, 60 Hz resistive. - 5 A @ 240 VAC, 60 Hz resistive. 1.082 in. dia. (28 mm) 0.50 in. ± 0.045 (12.7 mm ± 1.14) 2.0 in. ± 0.25 (51 mm ± 6.
7 UP Series Accessories Packaged dielectric isolating valve sets D B C TM04 9909 0311 F E Pump connection Pipe connection type and size Bronze GF 15/26 flange NPT TM03 7901 0307 A Material number Approx. shipping weight (1 kit) Face to face [A*] Center of port to top [B*] Flange diameter [C*] Center of valve to handle end [D*] [lb (kg)] [inch (mm)] [inch (mm)] [inch (mm)] [inch (mm)] 96806129 96806130 96806131 96806132 96806133 96806134 96806135 96806136 96806137 96806138 2.8 (1.
7 UP Series GF 15/26/40/43 GF 50 A B Pipe connection 2" NPT (51 mm) D C Pipe connection E F GU 125 union B Isolating valve GU 125 union Pipe connection Pipe connection D D A Pipe connection NPT Solder Compression 3/4" GF15/26 Cast iron Product number B TM04 9811 0111 B Pump connection A TM04 9809 0111 C C Dimensions (in. / mm) A B C D E F 4.25 (106) 3.13 (80) 2.75 (67) .50 (13) .50 (13) .
7 UP Series Accessories UP-ZV zone valves Specifications Grundfos UP-ZV 24 V, 2-way motorized zone valves for hydronic heating or chilled water applications. Standard features • In-line removable actuator for ease of installation and service • manual open/close lever • sealed end switch • silent close-off technology • high gear ratio • forged brass body • removable service cap • high Cv rating. TM04 9803 0111 Approvals Technical data Max. percent glycol: 50 % Fluid temp.
7 UP Series Connection size Flow coefficient Max. close-off ΔP 1/2-inch Sweat 3.5 Cv (3.0 Kv) 30 psi (207 kPa) 3/4-inch Sweat 7.5 Cv (6.5 Kv) 20 psi (138 kPa) 1-inch Sweat 7.5 Cv (6.5 Kv) 20 psi (138 kPa) 3/4-inch NPT 3.5 Cv (3.0 Kv) 30 psi (207 kPa) Accessories UP-ZV flow characteristics SWEAT MODELS TM04 9804 0111 NPT MODELS Dimensions [inches] Connections A B C 1/2-inch Sweat 1.31 (33) 2.63 (67) 3/4-inch Sweat 1.38 (35) 2.63 (67) 1-inch Sweat 1.69 (43) 2.
7 UP Series Accessories Replacement flange gaskets 82 For use with flange set Product number Description GF 15/26 GF 40/43 GF 50 GF 65 GF 80 GF 100 GU 125 510179 530244 96409353 550097 560185 570008 520089 Single gasket for 1-1/4" flange Single gasket for 1-1/2" flange Single gasket for 2" flange Single gasket for 2-1/2" flange Single gasket for 3" flange Single gasket for 4" flange Single gasket for GU 125 union Approx. shipping weight [lb (kg)] .25 .25 .25 .25 .25 .25 .25 (.6) (.6) (.6) (.
Being responsible is our foundation Thinking ahead makes it possible Innovation is the essence L-UP-PG-001 0113 The name Grundfos, the Grundfos logo, and the payoff be think innovate are registered trademarks owned by Grundfos Holding A/S or Grundfos A/S, Denmark. All rights reserved worldwide. ECM: - GRUNDFOS Pumps Corporation 17100 West 118th Terrace Olathe, Kansas 66061 Phone: +1-913-227-3400 Telefax: +1-913-227-3500 GRUNDFOS Canada Inc.