Brochure

Table Of Contents
Technical data
UP Series
6
64
UP 26-96 F/BF
Approvals
Note: Dimensions in inches unless otherwise noted.
TM03 5556 4412
0 2 4 6 8 10 12 14 16 18 20 22 24 Q [US GPM]
0
2
4
6
8
10
12
14
16
18
20
22
24
26
28
30
[ft]
H
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 Q [m³/h]
0
1
2
3
4
5
6
7
8
9
[m]
H
UP26-96F/BF
60 Hz
Flow range: 0-28 gpm (0-6.4 m
3
h)
Head range: 0-30 ft (0-9.1 m)
Motors: 2-pole, single-phase
Max. liquid temperature: 230 °F (110 °C)
Min. liquid temperature: 36 °F (2 °C)
Max. system pressure: 145 psi (10 bar)
Closed system (F) and open system (BF)
Model Volts Amps Watts Hp Capacitor
UP 26-96 F/BF
115 1.7 205 1/12 10 μF/180 V
230 0.8 205 1/12 2.5 μF/380 V
UP 26-96 F/BF
UP 26-96 BF
UP 26-96 F UP 26-96 BF
TM03 8533 1907
TM03 8543 1907
Model
Product number Dimensions [inches (mm)]
Connection type
and size
Shipping
weight
[lbs (kg)]
115 V 230 V A B C D E F
UP 26-96 F 52722341 52722338 6.50 (165) 6.38 (162) 5.06 (129) 4.13 (105) 3.50 (89) 3.16 (80)
GF 15/26 flange
(2) 1/2" dia. bolt holes
11.3 (5.1)
UP 26-96 BF 52722336 52722334 6.50 (165) 6.38 (162) 5.06 (129) 4.13 (105) 3.50 (89) 3.16 (80)
GF 15/26 flange
(2) 1/2" dia. bolt holes
12.5 (5.7)