Brochure

Table Of Contents
Technical data
UP Series
6
67
UPS 26-99 FC/BFC
Approvals
Note: The check valve can be removed.
Dimensions in inches unless otherwise noted.
TM03 8195 4412
0 4 8 12 16 20 24 28 Q [US GPM]
0
4
8
12
16
20
24
28
[ft]
H
0 1 2 3 4 5 6 7 Q [m³/h]
0
2
4
6
8
[m]
H
UPS26-99FC/BFC
60 Hz
1
2
3
Flow range: 0-33 gpm (0-7.5 m
3
h)
Head range: 0-29 ft (0-8.8 m)
Motors: 2-pole, single-phase
Max. liquid temperature: 230 °F (110 °C)
Min. liquid temperature: 36 °F (2 °C)
Max. system pressure: 145 psi (10 bar)
Model
Spee
d
Volts Amps Watts Hp Capacitor
UPS 26-99 FC
3
115
1.8 197 1/6 20 μF/180 V
2 1.5 179 1/6 20 μF/180 V
1 1.3 150 1/6 20 μF/180 V
UPS 26-99 FC/BFC
3
230
0.9 196 1/6 5 μF/400 V
2 0.8 179 1/6 5 μF/400 V
1 0.7 150 1/6 5 μF/400 V
Without check valve
With check valve
UP 26-99 F/BFC UP 26-99 BFC
UPS 26-99 FC UPS 26-99 BFC
TM03 8757 2407
TM03 8757 2407
Model
Product number Dimensions [inches (mm)]
Connection type and
size
Shipping
weight
[lbs (kg)]
115 V 230 V A B C D E F
UPS 26-99 FC 52722512 52722513 6.50 (165) 6.00 (152) 4.88 (124) 3.50 (89) 3.44 (87) 3.16 (80)
GF 15/26 flange
(2) 1/2" dia. bolt holes
10.3 (4.7)
UPS 26-99 BFC 52722518 52722519 6.50 (165) 6.00 (152) 4.88 (124) 3.50 (89) 3.44 (87) 3.16 (80)
GF 15/26 flange
(2) 1/2" dia. bolt holes
10.3 (4.7)