Technical data
38
Note: If the UP pump is equipped with a timer, the maximum liquid tem-
perature is 150 °F (66 °C).
Approvals
Note: LC/TLC Models have 6 ft (1.8 m), 3-prong power cord. Removable check valve.
Dimensions in inches unless otherwise noted.
TM03 8850 2607
0 2 4 6 8 10 12 14 16 18 20 22 24
Q[GPM]
0
1
2
3
4
5
6
7
8
9
10
11
12
[ft]
H
3
2
1
1
2
3
Flow range: 0-21.5 gpm
Head range: 0-12 feet
Motors: 2-pole, single-phase
Max. liquid temperature: 165 °F (74 °C)
Min. liquid temperature: 36 °F (2 °C)
Max. system pressure: 145 psi (10 bar)
Model Spd Volts Amps Watts Hp Capacitor
UPS 15-35 SUC/SFC
3
115
0.95 110 0.15
10μF/180 V2 0.75 84 0.11
1 0.55 61 0.08
Without check valve
With check valve
UPS 15-35 SFC UPS 15-35 SUC/TLC
TM03 8779 2507
TM03 8778 2507
Model type Product number
Dimensions [inches]
Connection type
and size
Shipping
weight [lbs]
ABCD EF
UPS 15-35 SFC 59896772 6 1/2 5 1/2 4 1/8 3 7/8 2 15/16 3 1/8 GF15/26 6
UPS 15-35 SUC 59896778 5 7/8 5 1/16 4 1/8 3 7/16 2 15/16 - GU125 5.4
UPS 15-35 SUC/TLC 59896780 5 7/8 5 1/16 4 1/8 3 7/16 2 15/16 - GU125 6.2
UPS 15-35 SUC/SFC