UPSeries.
UPSeries.
UPSeries.
UPSeries.
UPSeries.
UPSeries.book Page 6 Tuesday, September 18, 2007 1:01 PM Cross-reference UP Series TACO Competitor cross-reference Open systems: Stainless steel and bronze body pumps Comparable Grundfos replacement options Primary model (s) Taco pumps* Page Conn. type Pump length Model Conn.
UPSeries.book Page 7 Tuesday, September 18, 2007 1:01 PM Cross-reference UP Series Bell & Gossett Competitor cross-reference Open systems: Stainless steel and bronze body pumps Comparable Grundfos replacement options Primary model(s) Bell & Gossett Page Conn. type Pump length Model UP 15-10B5 28 1/2" sweat 5 NBF-8S/LW Conn.
UPSeries.book Page 8 Tuesday, September 18, 2007 1:01 PM Cross-reference UP Series ARMSTRONG Competitor cross-reference Open systems: Stainless steel and bronze body pumps Comparable Grundfos replacement options Primary model(s) Armstrong pumps* Page Conn. type Pump length Model Conn.
UPSeries.book Page 9 Tuesday, September 18, 2007 1:01 PM Cross-reference UP Series Discontinued products The table shows which new products replace discontinued products.
UPSeries.book Page 10 Tuesday, September 18, 2007 1:01 PM Performance ranges UP Series Super Brute team - Multi Speed H [ft] A. UPS 15-58 FC B. UPS 26-99 FC C. UPS 43-44 FC 32 28 24 20 B 16 12 4 A C 0 0 4 8 12 16 20 24 28 32 36 40 44 48 52 56 60 64 Q [US GPM] TM03 9130 3507 8 Comfort pump H [ft] 5.0 b 4.5 4.0 a 3.5 3.0 2.5 2.0 1.5 0.5 0.0 0.0 0.4 0.8 1.2 1.6 2.0 2.4 2.8 3.2 3.6 4.0 Q [US GPM] Note: a. UP 10-16B5 b. UP 10-16BN5 10 TM03 8851 2807 1.
UPSeries.book Page 11 Tuesday, September 18, 2007 1:01 PM Performance ranges UP Series Closed systems H [ft] 36 1. 2. 3. 4. 5. 6. 7. 8. 9. 1 32 2 28 4 24 UP 26-116 F UP 26-99 F UP 43-75 F UP 26-96 F UP 26-64 F UP 15-42 F UP 15-10 F/FR UP 15-100 F UP 26-120 U 5 20 3 8 16 6 12 8 0 0 4 8 12 16 20 24 28 32 36 40 44 Q [US GPM] TM03 9128 3407 9 7 4 Open systems H [ft] 32 10. UP 26-99 BF 11. UP 43-75 BF 12. UP 26-96 BF 13. UPS 15-55 SU/SF 14. UPS 15-35 SU/SF 15. UP 15-29 SU/SF 16.
UPSeries.book Page 12 Tuesday, September 18, 2007 1:01 PM Performance ranges UP Series Open systems 1/2" H [ft] 1. UP 15-42 B5 2. UP 15-18 B5 3. UP 15-10 B5 4. UP 15-42 BUC5 5. UP 15-18 BUC5 6. UP 15-10 BUC5 4 15 14 13 12 11 10 9 8 1 7 6 5 5 4 2 3 3 1 0 0 1 2 3 4 5 6 7 8 9 10 11 12 Q [US GPM] TM03 9131 3507 6 2 Open systems 3/4" H [ft] 7. UP 15-42 B7 8. UP 15-18 B7 9. UP 15-10 B7 10. UP 15-42 BUC7 11. UP 15-18 BUC7 12.
UPSeries.book Page 13 Tuesday, September 18, 2007 1:01 PM Product range UP Series Bronze Material 115 V 230 V Flow [ gpm] Head [ ft] UP 10-16B5/LC 96433894 - 0-3 0-5.4 z 27 UP 10-16B5/TLC 96433895 - 0-3 0-5.4 z 27 UP 10-16B5/ATLC 96433896 - 0-3 0-5.4 z 27 UP 10-16BN5/LC 96433897 - 0-3 0-5.4 z 27 UP 10-16BN5/TLC 96433898 - 0-3 0-5.4 z 27 UP 10-16BN5/ATLC 96433899 - 0-3 0-5.4 z UP 10-16BU/ATLC 96433902 - 0-3 0-5.
UPSeries.book Page 14 Tuesday, September 18, 2007 1:01 PM Product range UP Series Stainless steel Open systems UP 15-10SU7P/TLC* UP 15-29SF Material 115 V Flow [ gpm] Head [ ft] 595916 - 0-3.4 0-3.
UPSeries.book Page 15 Tuesday, September 18, 2007 1:01 PM Product range UP Series Cast iron Closed systems Material 115 V 230 V Flow [ gpm] Head [ ft] Flanged Union NPT Sweat Check valve Page UP 15-10F 59896248 - 0-8 0-5.5 z 30 UP 15-10FR 59896249 - 0-8 0-5.
UPSeries.
UPSeries.
UPSeries.
UPSeries.book Page 19 Tuesday, September 18, 2007 1:01 PM Nameplate description UP Series Nameplate NONSUBMERSIBLE CIRCULATION PUMP Type UP 15 - 42F P/N: 59896155 115 V 1PH PC: 0452 P1 60Hz US 10uF Class F IMPEDANCE PROTECTED I1/1 (A) P1 (W) .74 85 - FOR INDOOR USE ONLY MAX FLUID TEMP. 230F 99K4 C UL US LISTED NONSUBMERSIBLE CIRCULATION PUMP Type UP 15 - 42F P/N: 59896155 115 V 1PH PC: 0452 P1 60Hz US 10uF Class F IMPEDANCE PROTECTED I1/1 (A) P1 (W) .74 85 - FOR INDOOR USE ONLY MAX FLUID TEMP.
UPSeries.book Page 20 Tuesday, September 18, 2007 1:01 PM Applications The Grundfos circulator pumps, Series UP, are specifically designed for heating systems. The pumps are also suitable for circulation of hot domestic water and for circulation of liquid in cooling and airconditioning systems.
UPSeries.book Page 21 Tuesday, September 18, 2007 1:01 PM Applications UP Series Materials of construction Installation Description (UP closed systems) Material The pump must always be installed with horizontal motor shaft. Inlet cone, bearing plate, bearing retainers, rotor can, rotor cladding, shaft retainer 304 stainless steel Stator housing Aluminium Shaft, upper and lower radial bearings Aluminium oxide ceramic UP can be installed in both vertical and horizontal lines.
UPSeries.book Page 22 Tuesday, September 18, 2007 1:01 PM Applications UP Series Pumped liquids Maximum system pressure Depending on type, Grundfos circulator pumps are designed for the following liquids: 145 psi (10 bar). Minimum inlet pressure • Potable water The amount of pressure required at the inlet of a pump is a function of the temperature of the water as shown in the table below.
UPSeries.book Page 23 Tuesday, September 18, 2007 1:01 PM Applications UP Series The Grundfos MixiMizer, a fully integrated injection pump and indoor/outdoor controller, is the only pump and controller system of its kind. Equipped with a weather responsive control, also known as indoor/outdoor control or reset control, the MixiMizer automatically calculates and controls mixed water temperatures according to outdoor temperatures in primary/secondary piping systems.
UPSeries.book Page 24 Tuesday, September 18, 2007 1:01 PM Applications UP Series Variable-speed pump H [ft] 32 d 28 If desired, the manual-% dial allows the speed of the pump to be manually adjusted and set by the user. The speed of the pump may be manually adjusted anywhere from min. to 100 %, but once set, remains fixed at that speed.
UPSeries.book Page 25 Tuesday, September 18, 2007 1:01 PM Applications UP Series Comfort system The Comfort system uses a patented Comfort valve and pump to provide instant availability of hot water at the point of use. Operation The Comfort valve is installed at the furthest fixture from the hot-water tank. With a built-in timer, the pump allows hot water to circulate along the loop through the valve using the cold-water side as a return line.
UPSeries.book Page 26 Tuesday, September 18, 2007 1:01 PM Applications UP Series Comfort pump The water-conduction part of the pump is hermetically separated from the stator with a stainless steel spherical separator. The motor can be separated from the pump housing, enabling easy maintenance and replacement. Applications • Domestic hot-water recirculation systems in singleand two-family houses Ambient and liquid temperatures Liquid temperature: 36 °F (2 °C) to 203 °F (95 °C).
UPSeries.book Page 27 Tuesday, September 18, 2007 1:01 PM Technical data UP Series UP 10-16B5/BN5 UP 10 Comfort Pump Flow range: Head range: Motors: Max. liquid temperature: Min. liquid temperature: Max. system pressure: H [ft] 5.0 b 4.5 4.0 a 3.5 Model 0-3.5 U.S. gpm 0-5.4 feet Single-phase 203 °F (95 °C) 36 °F (2 °C) 145 psi Volts Amps Watts Hp Capacitor 115 0.23 25 - - 3.0 UP 10-16B5/BN5 2.5 Position System type Description a Open UP 10-16B5 b Open UP 10-16BN5 2.0 1.5 0.
UPSeries.book Page 28 Tuesday, September 18, 2007 1:01 PM Technical data UP Series UP 15-10B5/B7 UP 15 Flow range: Head range: Motors: Max. liquid temperature: Min. liquid temperature: Max. system pressure: H [ft] 7 b a Note: If the UP pump is equipped with a timer, the maximum liquid temperature is 150 °F (66 °C).
UPSeries.book Page 29 Tuesday, September 18, 2007 1:01 PM Technical data H [ft] UP Series UP 15-10BUC5/7 Flow range: Head range: Motors: Max. liquid temperature: Min. liquid temperature: Max. system pressure: a 6.5 6.0 5.5 b 5.0 0-6.6 U.S. gpm 0-6.6 feet 2-pole, single-phase 230 °F (110 °C) 36 °F (2 °C) 145 psi Note: If the UP pump is equipped with a timer, the maximum liquid temperature is 150 °F (66 °C). 4.5 4.0 Model 3.5 UP 15-10BUC5/BUC7 Volts Amps Watts Hp Capacitor 115 0.
UPSeries.book Page 30 Tuesday, September 18, 2007 1:01 PM Technical data UP Series UP 15-10F/FR Flow range: Head range: Motors: Max. liquid temperature: Min. liquid temperature: Max. system pressure: Closed system H [ft] 6 5 4 Model UP 15-10F/FR 0-8.0 U.S. gpm 0-5.5 feet 2-pole, single-phase 230 °F (110 °C) 36 °F (2 °C) 145 psi Volts Amps Watts Hp Capacitor 115 0.
UPSeries.book Page 31 Tuesday, September 18, 2007 1:01 PM Technical data UP Series UP 15-10SU7P/TLC Comfort system Flow range: Head range: Motors: Max. liquid temperature: Min. liquid temperature: Max. system pressure: Open system H [ft] 5.0 4.5 4.0 3.5 Model 3.0 UP 15-10SU7P/TLC 2.5 0-6.3 U.S. gpm 0-5.1 feet Single-phase 150 °F (66 °C) 36 °F (2 °C) 145 psi Volts Amps Watts Hp Capacitor 115 0.23 25 1/25 2μF/400 V Approvals 2.0 • ANSI/NSF61 • IAPMO 1.0 • UPC 0.5 0.0 0.0 0.5 1.0 1.
UPSeries.book Page 32 Tuesday, September 18, 2007 1:01 PM Technical data UP Series UP 15-18B5/B7 Flow range: Head range: Motors: Max. liquid temperature: Min. liquid temperature: Max. system pressure: H [ft] 14 13 12 11 10 0-14.7 U.S. gpm 0-13.9 feet 2-pole, single-phase 230 °F (110 °C) 36 °F (2 °C) 145 psi Note: If the UP pump is equipped with a timer, the maximum liquid temperature is 150 °F (66 °C). 9 Model 8 7 UP 15-18B5 6 UP 15-18B7 5 Volts Amps Watts Hp Capacitor 115 0.
UPSeries.book Page 33 Tuesday, September 18, 2007 1:01 PM Technical data UP Series UP 15-18BUC5/BUC7 Flow range: Head range: Motors: Max. liquid temperature: Min. liquid temperature: Max. system pressure: H [ft] 16 b 14 a 0-14.7 U.S. gpm 0-14.5 feet 2-pole, single-phase 230 °F (110 °C) 36 °F (2 °C) 145 psi 12 Model 10 Volts Amps Watts Hp Capacitor UP 15-18BUC5 115 0.55 60 1/25 8μF/180 V UP 15-18BUC7 115 0.
UPSeries.book Page 34 Tuesday, September 18, 2007 1:01 PM Technical data UP Series UP 15-18SF Flow range: Head range: Motors: Max. liquid temperature: Min. liquid temperature: Max. system pressure: Open system H [ft] 7 6 0-12 U.S. gpm 0-7 feet 2-pole, single-phase 230 °F (110 °C) 36 °F (2 °C) 145 psi 5 Model 4 UP 15-18SF Volts Amps Watts Hp Capacitor 230 0.
UPSeries.book Page 35 Tuesday, September 18, 2007 1:01 PM Technical data UP Series UP 15-29SU/SF Flow range: Head range: Motors: Max. liquid temperature: 0-20.5 U.S. gpm 0-9.7 feet 2-pole, single-phase 230 °F (110 °C) and 150 °F for UP 15-29SU/TLC Min. liquid temperature: 36 °F (2 °C) Max. system pressure: 145 psi Open system H [ft] 10 9 8 7 6 Note: If the UP pump is equipped with a timer, the maximum liquid temperature is 150 °F (66 °C).
UPSeries.book Page 36 Tuesday, September 18, 2007 1:01 PM Technical data UP Series UP 15-35SUC Flow range: Head range: Motors: Max. liquid temperature: Min. liquid temperature: Max. system pressure: Open system H [ft] 12 10 8 Model UP 15-35SUC 0-17.5 U.S. gpm 0-11.5 feet 2-pole, single-phase 230 °F (110 °C) 36 °F (2 °C) 145 psi Volts Amps Watts Hp Capacitor 230 0.42 114 0.
UPSeries.book Page 37 Tuesday, September 18, 2007 1:01 PM Technical data UP Series UPS 15-35SUC/SFC Super Brute Flow range: Head range: Motors: Max. liquid temperature: Min. liquid temperature: Max. system pressure: H [ft] 12 3 11 10 9 0-21.5 U.S. gpm 0-12 feet 2-pole, single-phase 165 °F (74 °C) 36 °F (2 °C) 145 psi Note: If the UP pump is equipped with a timer, the maximum liquid temperature is 150 °F (66 °C). 8 2 Model 7 Spd Volts Amps 3 6 UPS 15-35SUC/SFC 5 2 Watts Hp 110 0.15 0.
UPSeries.book Page 38 Tuesday, September 18, 2007 1:01 PM Technical data UP Series UP 15-42B5/B7 Flow range: Head range: Motors: Max. liquid temperature: Min. liquid temperature: Max. system pressure: H [ft] 16 b 14 a Note: If the UP pump is equipped with a timer, the maximum liquid temperature is 150 °F (66 °C). 10 Model UP 15-42 B5 8 UP 15-42 B7 6 2 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 Q [US GPM] Model type Watts Hp Capacitor 0.74 85 1/25 10μF/180 V 230 0.
UPSeries.book Page 39 Tuesday, September 18, 2007 1:01 PM Technical data UP Series UP 15-42BUC5/BUC7 Flow range: Head range: Motors: Max. liquid temperature: Min. liquid temperature: Max. system pressure: H [ft] 16 14 0-17 U.S. gpm 0-15 feet 2-pole, single-phase 205 °F (96 °C) 36 °F (2 °C) 145 psi 12 Model 10 Volts Amps Watts Hp Capacitor UP 15-42BUC5 115 0.74 85 1/25 10μF/180 V UP 15-42BUC7 115 0.
UPSeries.book Page 40 Tuesday, September 18, 2007 1:01 PM Technical data UP Series UP 15-42BUC5/MR and BUC7/MR MixiMizer Flow range: Head range: Motors: Max. liquid temperature: Min. liquid temperature: Max. system pressure: H [ft] 16 c 14 0-13.5 U.S. gpm 0-15 feet 2-pole, single-phase 205 °F (96 °C) 36 °F (2 °C) 145 psi b 12 Model 10 Volts Amps Watts Hp Capacitor UP 15-42 BUC5/MR 115 0.74 85 1/25 10μF/180 V UP 15-42 BUC7/MR 115 0.
UPSeries.book Page 41 Tuesday, September 18, 2007 1:01 PM Technical data UP Series UP 15-42FC/MR MixiMizer Flow range: Head range: Motors: Max. liquid temperature: Min. liquid temperature: Max. system pressure: H [ft] 16 b 14 0-16 U.S. gpm 0-15 feet 2-pole, single-phase 205 °F (96 °C) 36 °F (2 °C) 145 psi 12 Model UP 15-42FC/MR 10 8 6 Volts Amps Watts Hp Capacitor 115 0.74 85 1/25 10μF/180 V Position System type a Closed Description Min. curve b Closed Max.
UPSeries.book Page 42 Tuesday, September 18, 2007 1:01 PM Technical data UP Series UP 15-42F/FR 12 Flow range: Head range: Motors: Max. liquid temperature: Min. liquid temperature: Max. system pressure: Closed system 10 Model H [ft] 16 14 UP 15-42 F/FR 8 0-17 U.S. gpm 0-15 feet 2-pole, single-phase 230 °F (110 °C) 36 °F (2 °C) 145 psi Volts Amps Watts Hp Capacitor 115 0.74 85 1/25 10μF/180 V 230 0.
UPSeries.book Page 43 Tuesday, September 18, 2007 1:01 PM Technical data UP Series UP 15-42F/VS Variable Speed Flow range: Head range: Motors: Max. liquid temperature: Min. liquid temperature: Max. system pressure: H [ft] 16 b 14 12 Model UP 15-42 F/FV 10 8 6 0-16 U.S. gpm 0-15.5 feet 2-pole, single-phase 205 °F (96 °C) 36 °F (2 °C) 145 psi Volts Amps Watts Hp Capacitor 115 0.74 85 1/25 10μF/180 V Position System type a Closed Description Min. curve b Closed Max.
UPSeries.book Page 44 Tuesday, September 18, 2007 1:01 PM Technical data UP Series UPS 15-42F/FR Flow range: Head range: Motors: Max. liquid temperature: Min. liquid temperature: Max. system pressure: H [ft] 16 3 14 0-17.5 U.S. gpm 0-15.5 feet 2-pole, single-phase 230 °F (110 °C) 36 °F (2 °C) 145 psi 2 12 Model Spd Volts 3 10 UPS 15-42F/FR 8 1 6 UPS 15-42F 2 0 0 2 4 6 8 10 12 14 16 18 Q [US GPM] TM03 5574 0907 2 Hp Capacitor 85 1/25 10μF/180 V - 0.57 65 - 0.
UPSeries.book Page 45 Tuesday, September 18, 2007 1:01 PM Technical data UP Series UPS 15-55SFC/SUC Super Brute Flow range: Head range: Motors: Max. liquid temperature: Min. liquid temperature: Max. system pressure: H [ft] 18 3 16 2 14 0-25 U.S. gpm 0-18 feet 2-pole, single-phase 230 °F (110 °C) 36 °F (2 °C) 145 psi Note: If the UP pump is equipped with a timer, the maximum liquid temperature is 150 °F (66 °C).
UPSeries.book Page 46 Tuesday, September 18, 2007 1:01 PM Technical data UP Series UP15-55SUC Flow range: Head range: Motors: Max. liquid temperature: Min. liquid temperature: Max. system pressure: Closed system H [ft] 18 16 14 0-21.5 U.S. gpm 0-17 feet 2-pole, single-phase 230 °F (110 °C) 36 °F (2 °C) 145 psi 12 Model UP 15-55SUC 10 Volts Amps Watts Hp Capacitor 230 0.42 97 0.
UPSeries.book Page 47 Tuesday, September 18, 2007 1:01 PM Technical data UP Series UPS 15-58FC/FRC Super Brute Flow range: Head range: Motors: Max. liquid temperature: Min. liquid temperature: Max. system pressure: H [ft] 20 3 18 2 16 Model 14 Spd 1 Volts 0-17 U.S. gpm 0-19.5 feet 2-pole, single-phase 230 °F (110 °C) 36 °F (2 °C) 145 psi Amps Watts 0.75 87 1/25 10μF/180 V 0.66 80 1/25 10μF/180 V 0.
UPSeries.book Page 48 Tuesday, September 18, 2007 1:01 PM Technical data UP Series UP 15-100F Flow range: Head range: Motors: Max. liquid temperature: Min. liquid temperature: Max. system pressure: Closed system H [ft] 36 32 28 0-8.4 U.S. gpm 0-36 feet 2-pole, single-phase 205 °F (96 °C) 36 °F (2 °C) 145 psi 24 Model UP 15-100F 20 Volts Amps Watts Hp Capacitor 115 1.
UPSeries.book Page 49 Tuesday, September 18, 2007 1:01 PM Technical data UP Series UP 26-64F UP 26 Flow range: Head range: Motors: Max. liquid temperature: Min. liquid temperature: Max. system pressure: Closed system H [ft] 26 24 22 20 0-32 U.S. gpm 0-24.5 feet 2-pole, single-phase 230 °F (110 °C) 36 °F (2 °C) 145 psi 18 16 Model 14 UP 26-64F 12 Volts Amps Watts Hp 115 1.7 185 1/12 Capacitor 8μF/180 V 230 0.8 175 1/12 2.
UPSeries.book Page 50 Tuesday, September 18, 2007 1:01 PM Technical data UP Series UP 26-64F/VS Variable Speed Flow range: Head range: Motors: Max. liquid temperature: Min. liquid temperature: Max. system pressure: H [ft] b 24 20 Model UP 26-64F/VS 16 12 0-34 U.S. gpm 0-24.5 feet 2-pole, single-phase 205 °F (96 °C) 36 °F (2 °C) 145 psi Volts Amps Watts Hp Capacitor 115 1.7 185 1/12 8μF/180 V Position System type a Closed Description Min. curve b Closed Max.
UPSeries.book Page 51 Tuesday, September 18, 2007 1:01 PM Technical data UP Series UP 26-96F/BF Flow range: Head range: Motors: Max. liquid temperature: Min. liquid temperature: Max. system pressure: Closed system (F) and open H [ft] 30 28 26 24 22 0-28 U.S. gpm 0-30 feet 2-pole, single-phase 230 °F (110 °C) 36 °F (2 °C) 145 psi system (BF) 20 Model 18 16 UP 26-96F/BF 14 Volts Amps Watts Hp Capacitor 115 1.7 205 1/12 10μF/180 V 230 0.8 205 1/12 2.
UPSeries.book Page 52 Tuesday, September 18, 2007 1:01 PM Technical data UP Series UP 26-96F/VS Variable Speed Flow range: Head range: Motors: Max. liquid temperature: Min. liquid temperature: Max. system pressure: H [ft] 32 b 28 24 Model UP 26-96 F/VS 20 16 12 0-28 U.S. gpm 0-30 feet 2-pole, single-phase 195 °F (91 °C) 36 °F (2 °C) 145 psi Volts Amps Watts Hp Capacitor 115 1.7 205 1/12 10μF/180 V Position System type a Closed Description Min. curve b Closed Max.
UPSeries.book Page 53 Tuesday, September 18, 2007 1:01 PM Technical data UP Series UP 26-99F/BF 24 Flow range: 0-34 U.S. gpm Head range: 0-32 feet Motors: 2-pole, single-phase Max. liquid temperature: 230 °F (110 °C) Min. liquid temperature: 36 °F (2 °C) Max. system pressure: 145 psi Closed system (F) and Open system (BF) 20 Model H [ft] 32 28 UP 26-99F/BF 16 Volts Amps Watts Hp Capacitor 115 2.15 245 1/6 10μF/180 V 230 1.07 245 1/6 2.
UPSeries.book Page 54 Tuesday, September 18, 2007 1:01 PM Technical data UP Series UPS 26-99FC/BFC Super Brute Flow range: Head range: Motors: Max. liquid temperature: Min. liquid temperature: Max. system pressure: H [ft] 3 28 2 24 0-33 U.S. gpm 0-29 feet 2-pole, single-phase 230 °F (110 °C) 36 °F (2 °C) 145 psi 1 20 Model Spd Volts Amps Watts Hp Capacitor 1.8 197 1/6 20μF/180 V 3 UPS 26-99FC 16 2 12 UPS 26-99FC/BFC 1.5 179 1/6 20μF/180 V 1 1.3 150 1/6 20μF/180 V 3 0.
UPSeries.book Page 55 Tuesday, September 18, 2007 1:01 PM Technical data UP Series UP 26-116F/BF Flow range: 0-37 U.S. gpm Head range: 0-37 feet Motors: 2-pole, single-phase Max. liquid temperature: 150 °F (65 °C) Min. liquid temperature: 32 °F (0 °C) Max. system pressure: 145 psi Closed system (F) and Open system (BF) H [ft] 40 36 32 28 Model 24 UP 26-116F/BF Volts Amps Watts Hp Capacitor 230 1.8 385 1/6 2.
UPSeries.book Page 56 Tuesday, September 18, 2007 1:01 PM Technical data UP Series UP 26-120U Flow range: Head range: Motors: Max. liquid temperature: Min. liquid temperature: Max. system pressure: Closed system H [ft] 40 36 32 0-19 U.S. gpm 0-38 feet 2-pole, single-phase 203 °F (95 °C) 32 °F (0 °C) 145 psi 28 Model 24 UP 26-120U 20 Volts Amps Watts Hp Capacitor 115 2.15 215 1/6 10μF/180 V 230 1.07 220 1/6 2.
UPSeries.book Page 57 Tuesday, September 18, 2007 1:01 PM Technical data UP Series UP 43-44F/BF UP 43 Flow range: Head range: Motors: Max. liquid temperature: Min. liquid temperature: Max. system pressure: Closed system (F) and open H [ft] 14 13 12 11 10 0-68 U.S. gpm 0-13.5 feet 2-pole, single-phase 230 °F (110 °C) 32 °F (0 °C) 145 psi system (BF) 9 Model 8 UP 43-44F/BF 7 Volts Amps Watts Hp Capacitor 115 2.15 215 1/6 10μF/180 V 230 1.07 220 1/6 2.
UPSeries.book Page 58 Tuesday, September 18, 2007 1:01 PM Technical data UP Series UPS 43-44FC/BFC Super Brute Flow range: Head range: Motors: Max. liquid temperature: Min. liquid temperature: Max. system pressure: H [ft] 14 3 2 12 Model 10 Spd 1 Volts 0-63 U.S. gpm 0-14 feet 2-pole, single-phase 230 °F (110 °C) 32 °F (0 °C) 145 psi Amps Watts Hp Capacitor 1.8 203 1/6 20μF/180 V 3 UPS 43-44FC/BFC 8 6 UPS 43-44FC/BFC 2 1.7 189 1/6 20μF/180 V 1 1.4 157 1/6 20μF/180 V 3 0.
UPSeries.book Page 59 Tuesday, September 18, 2007 1:01 PM Technical data UP Series UP 43-75BF Flow range: Head range: Motors: Max. liquid temperature: Min. liquid temperature: Max. system pressure: Open system H [ft] 26 24 22 20 18 16 Model 14 UP 43-75F/BF 12 0-41 U.S. gpm 0-25 feet 2-pole, single-phase 230 °F (110 °C) 36 °F (2 °C) 145 psi Volts Amps Watts Hp Capacitor 115 2.15 215 1/6 10μF/180 V 230 1.07 220 1/6 2.
UPSeries.book Page 60 Tuesday, September 18, 2007 1:01 PM Technical data UP Series UP 43-100F Flow range: Head range: Motors: Max. liquid temperature: Min. liquid temperature: Max. system pressure: Closed system H [ft] 40 36 32 0-98 U.S. gpm 0-37 feet 2-pole, single-phase 230 °F (110 °C) 14 °F (–10 °C) 145 psi 28 Model 24 UP 43-110F 20 Volts Amps Watts Hp Capacitor 115 5.1 590 3/4 60μF 230 2.
UPSeries.book Page 61 Tuesday, September 18, 2007 1:01 PM Technical data UP Series UP 50-44F UP 50 Flow range: Head range: Motors: Max. liquid temperature: Min. liquid temperature: Max. system pressure: Closed system H [ft] 14 13 12 11 10 0-64 U.S. gpm 0-13.4 feet 2-pole, single-phase 230 °F (110 °C) 32 °F (0 °C) 145 psi 9 Model 8 UP 50-44F 7 Volts Amps Watts Hp 115 2.15 215 1/6 Capacitor 10μF 230 1.07 220 1/6 2.
UPSeries.book Page 62 Tuesday, September 18, 2007 1:01 PM Technical data H [ft] UP Series UPS 50-44F Flow range: Head range: Motors: Max. liquid temperature: Min. liquid temperature: Max. system pressure: 3 14 2 13 12 11 1 0-65 U.S. gpm 0-14.4 feet 2-pole, single-phase 230 °F (110 °C) 32 °F (0 °C) 145 psi 10 Model 9 Spd Volts Amps Watts Hp 1.9 195 1/6 1.8 182 1/6 1.5 147 1/6 3 8 2 7 1 UPS 50-44F 115 3 6 2 5 230 1 4 1 195 1/6 0.9 182 1/6 0.
UPSeries.book Page 63 Tuesday, September 18, 2007 1:01 PM Technical data UP Series UP 50-75F Flow range: Head range: Motors: Max. liquid temperature: Min. liquid temperature: Max. system pressure: Closed system H [ft] 26 24 22 20 0-41 U.S. gpm 0-25 feet 2-pole, single-phase 230 °F (110 °C) 32 °F (0 °C) 145 psi 18 16 Model 14 UP 50-75F 12 Volts Amps Watts Hp Capacitor 115 2.15 215 1/6 10μF/180 V 230 1.07 220 1/6 2.
UPSeries.book Page 64 Tuesday, September 18, 2007 1:01 PM Accessories UP Series Fig. 10 UP timers UP timer Specifications (previous/current) Type: 24 hr. 3-position on/timer/off 15-minute interval • Size: 3.77 x 2.85 x 1.25". • Supply voltage: 120 VAC. • Power consumption: 1 VA. Switch rating: SPDT • Resistive: 21A/6 A. • Tungsten: 1350 W. • Inductive: 1 HP @ 120 VAC; 2 HP @ 240 VAC. TM03 4406 3507 Wiring connections: 1/4" quick-connects. Installation Indoor, wired and mounted on the UP terminal box.
UPSeries.book Page 65 Tuesday, September 18, 2007 1:01 PM Accessories UP Series AquaStat Specifications 1.082 DIA. Description: Thermostatic switch. ±0.045 0.50 Type: Bi-metallic disc, snap acting. Enclosure: environmentally sealed. Mounting: ±0.250 2.0 • Clip-on mount for 1/2” I.D. copper tube (5/8" O.D.). • Clip-on mount for 3/4” I.D. copper tube (7/8" O.D.). Contact rating: ±0.37 14.0 • 10 A @ 120 VAC, 60 Hz resistive. • 5 A @ 240 VAC, 60 Hz resistive.
UPSeries.book Page 66 Tuesday, September 18, 2007 1:01 PM Accessories UP Series TM03 7901 0307 Packaged dielectric isolation valve sets Fig. 15 Dielectric isolation valves Pump connection Pipe connection type and size Face to face [A*] Center of port to top [B*] Flange diameter [C*] [lb/oz.
UPSeries.
Accessories2.
Accessories2.
Accessories2.fm Page 70 Tuesday, September 18, 2007 1:19 PM Accessories UP Series Replacement flange gasket For use with flange set Material number Description Shipping weight [oz.
UPSeries.book Page 71 Tuesday, September 18, 2007 1:01 PM Submittal data UP Series Submittal data Company name ................................................. Prepared by ....................................................... Phone number (.......)......................................... Fax number (.......).............................................. Date:..................... Page 1 of:.................... Quote number:...................................................
UPSeries.book Page 72 Tuesday, September 18, 2007 1:01 PM Further product documentation UP Series WebCAPS WebCAPS is a Web-based Computer Aided Product Selection program available on www.grundfos.com. WebCAPS contains detailed information on more than 185,000 Grundfos products in more than 20 languages. In WebCAPS, all information is divided into 6 sections: • Catalogue • Literature • Service • Sizing • Replacement • CAD drawings.
UPSeries.book Page 73 Tuesday, September 18, 2007 1:01 PM Further product documentation Sizing 0 UP Series 1 This section is based on different fields of application and installation examples, and gives easy step-by-step instructions in how to • select the most suitable and efficient pump for your installation • carry out advanced calculations based on energy consumption, payback periods, load profiles, life cycle costs, etc.
UPSeries.
UPSeries.
UPSeries.book Page 76 Tuesday, September 18, 2007 1:01 PM Being responsible is our foundation Thinking ahead makes it possible Innovation is the essence L-UP-PG-001 Rev. 0907 Printed in the U.S.A. GRUNDFOS Pumps Corporation 17100 West 118th Terrace Olathe, Kansas 66061 Phone: +1-913-227-3400 Telefax: +1-913-227-3500 US GRUNDFOS Canada Inc. 2941 Brighton Road Oakville, Ontario L6H 6C9 Canada Phone: +1-905 829 9533 Telefax: +1-905 829 9512 Subject to alterations. Bombas GRUNDFOS de Mexico S.A. de C.V.