41
MixiMizer
TM03 8838 2607
0 2 4 6 8 10 12 14 16 18
Q [US GPM]
0
2
4
6
8
10
12
14
16
[ft]
H
b
a
Flow range: 0-16 U.S. gpm
Head range: 0-15 feet
Motors: 2-pole, single-phase
Max. liquid temperature: 205 °F (96 °C)
Min. liquid temperature: 36 °F (2 °C)
Max. system pressure: 145 psi
Model Volts Amps Watts Hp Capacitor
UP 15-42FC/MR 115 0.74 85 1/25 10μF/180 V
Position System type Description
a Closed Min. curve
b Closed Max. UP 15-42FC/MR
UP 15-42FC/MR
TM03 8528 1907
Model type Product number A B C D E F
Connection type
and size
Shipping weight
[lbs]
UP 15-42FC/MR 59896277 6 1/2 5 1/4 4 4 3/16 3 1/4 3 5/32
GF 15/26 flange
(2) 1/2" dia. bolt holes
7 1/2
UP Series
UP 15-42FC/MR
UPSeries.book Page 41 Tuesday, September 18, 2007 1:01 PM